| TABLE III. Group A inspection for device type 04.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Subgroup
Symbol
MIL-STD-
883
Case L
13
14
15
16
17
18
19
20
21
22
23
24
Measured
Test Limits
Unit
SEL BA
CLK BA
method
Test no.
B8
B7
B6
B5
B4
B3
B2
B1
VCC
terminal
Min
Max
G
1
VOH1
3006
1
-3 mA
0.5 V
0.5 V
0.5 V
4.5 V
B1
2.4
V
Tc = 25C
"
2
-3 mA
"
"
"
"
B2
"
"
"
3
-3 mA
"
"
"
"
B3
"
"
"
4
-3 mA
"
"
"
"
B4
"
"
"
5
-3 mA
"
"
"
"
B5
"
"
"
6
-3 mA
"
"
"
"
B6
"
"
"
7
-3 mA
"
"
"
"
B7
"
"
"
8
-3 mA
"
"
"
"
B8
"
"
"
9
2.0 V
"
"
"
"
A1
"
"
"
10
2.0 V
"
"
"
"
A2
"
"
"
11
2.0 V
"
"
"
"
A3
"
"
"
12
2.0 V
"
"
"
"
A4
"
"
"
13
2.0 V
"
"
"
"
A5
"
"
"
14
2.0 V
"
"
"
"
A6
"
"
"
15
2.0 V
"
"
"
"
A7
"
"
"
16
2.0 V
"
"
"
"
A8
"
"
VOH2
"
17
-12 mA
"
"
"
"
B1
2.0
"
"
18
-12 mA
"
"
"
"
B2
"
"
"
19
-12 mA
"
"
"
"
B3
"
"
"
20
-12 mA
"
"
"
"
B4
"
"
"
21
-12 mA
"
"
"
"
B5
"
"
"
22
-12 mA
"
"
"
"
B6
"
"
"
23
-12 mA
"
"
"
"
B7
"
"
"
24
-12 mA
"
"
"
"
B8
"
"
"
25
2.0 V
"
"
"
"
A1
"
"
"
26
2.0 V
"
"
"
"
A2
"
"
"
27
2.0 V
"
"
"
"
A3
"
"
"
28
2.0 V
"
"
"
"
A4
"
"
"
29
2.0 V
"
"
"
"
A5
"
"
"
30
2.0 V
"
"
"
"
A6
"
"
"
31
2.0 V
"
"
"
"
A7
"
"
"
32
2.0 V
"
"
"
"
A8
"
"
VOL
"
33
12 mA
"
"
"
"
B1
0.4
"
"
34
12 mA
"
"
"
"
B2
"
"
"
35
12 mA
"
"
"
"
B3
"
"
"
36
12 mA
"
"
"
"
B4
"
"
"
37
12 mA
"
"
"
"
B5
"
"
"
38
12 mA
"
"
"
"
B6
"
"
"
39
12 mA
"
"
"
"
B7
"
"
"
40
12 mA
"
"
"
"
B8
"
"
"
41
0.5 V
"
"
"
"
A1
"
"
"
42
0.5 V
"
"
"
"
A2
"
"
"
43
0.5 V
"
"
"
"
A3
"
"
"
44
0.5 V
"
"
"
"
A4
"
"
"
45
0.5 V
"
"
"
"
A5
"
"
"
46
0.5 V
"
"
"
"
A6
"
"
"
47
0.5 V
"
"
"
"
A7
"
"
"
48
0.5 V
"
"
"
"
A8
"
"
VI C
"
49
"
CAB
-1.5
"
"
50
"
SAB
"
"
"
51
"
DIR
"
"
"
52
"
A1
"
"
"
53
"
A2
"
"
"
54
"
A3
"
"
"
55
"
A4
"
"
"
56
"
A5
"
"
"
57
"
A6
"
"
"
58
"
A7
"
"
"
59
"
A8
"
"
See footnotes at end of device type 04.
|