| TABLE III. Group A inspection for device type 04.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.7 V; or open).
Subgroup
Symbol
MIL-STD-
883
Case L
13
14
15
16
17
18
19
20
21
22
23
24
Measured
Test Limits
Unit
SEL BA
CLK BA
method
Test no.
B8
B7
B6
B5
B4
B3
B2
B1
VCC
terminal
Min
Max
G
9
tPHL1
3003
217
OUT
GND
GND
GND
5.0 V
CAB to B1
2
40
ns
Tc = 25C
(fig. 3)
218
OUT
"
"
"
"
CAB to B2
"
"
"
"
219
OUT
"
"
"
"
CAB to B3
"
"
"
"
220
OUT
"
"
"
"
CAB to B4
"
"
"
"
221
OUT
"
"
"
"
CAB to B5
"
"
"
"
222
OUT
"
"
"
"
CAB to B6
"
"
"
"
223
OUT
"
"
"
"
CAB to B7
"
"
"
"
224
OUT
"
"
"
"
CAB to B8
"
"
"
"
225
IN
"
4.5 V
IN
"
CBA to A1
"
"
"
"
226
IN
"
"
"
"
CBA to A2
"
"
"
"
227
IN
"
"
"
"
CBA to A3
"
"
"
"
228
IN
"
"
"
"
CBA to A4
"
"
"
"
229
IN
"
"
"
"
CBA to A5
"
"
"
"
230
IN
"
"
"
"
CBA to A6
"
"
"
"
231
IN
"
"
"
"
CBA to A7
"
"
"
"
232
IN
"
"
"
"
CBA to A8
"
"
"
tPLH2
"
233
OUT
"
GND
GND
"
A1 to B1
"
23
"
"
234
OUT
"
"
"
"
A2 to B2
"
"
"
"
235
OUT
"
"
"
"
A3 to B3
"
"
"
"
236
OUT
"
"
"
"
A4 to B4
"
"
"
"
237
OUT
"
"
"
"
A5 to B5
"
"
"
"
238
OUT
"
"
"
"
A6 to B6
"
"
"
"
239
OUT
"
"
"
"
A7 to B7
"
"
"
"
240
OUT
"
"
"
"
A8 to B8
"
"
"
"
241
IN
"
"
"
"
B1 to A1
"
"
"
"
242
IN
"
"
"
"
B2 to A2
"
"
"
"
243
IN
"
"
"
"
B3 to A3
"
"
"
"
244
IN
"
"
"
"
B4 to A4
"
"
"
"
245
IN
"
"
"
"
B5 to A5
"
"
"
"
246
IN
"
"
"
"
B6 to A6
"
"
"
"
247
IN
"
"
"
"
B7 to A7
"
"
"
"
248
IN
"
"
"
"
B8 to A8
"
"
"
tPHL2
"
249
OUT
"
"
"
"
A1 to B1
"
25
"
"
250
OUT
"
"
"
"
A2 to B2
"
"
"
"
251
OUT
"
"
"
"
A3 to B3
"
"
"
"
252
OUT
"
"
"
"
A4 to B4
"
"
"
"
253
OUT
"
"
"
"
A5 to B5
"
"
"
"
254
OUT
"
"
"
"
A6 to B6
"
"
"
"
255
OUT
"
"
"
"
A7 to B7
"
"
"
"
256
OUT
"
"
"
"
A8 to B8
"
"
"
"
257
IN
"
"
"
"
B1 to A1
"
"
"
"
258
IN
"
"
"
"
B2 to A2
"
"
"
"
259
IN
"
"
"
"
B3 to A3
"
"
"
"
260
IN
"
"
"
"
B4 to A4
"
"
"
"
261
IN
"
"
"
"
B5 to A5
"
"
"
"
262
IN
"
"
"
"
B6 to A6
"
"
"
"
263
IN
"
"
"
"
B7 to A7
"
"
"
"
264
IN
"
"
"
"
B8 to A8
"
"
"
tPLH3
"
265
OUT
"
"
"
"
SAB to B1
"
45
"
"
266
OUT
"
"
"
"
SAB to B2
"
"
"
"
267
OUT
"
"
"
"
SAB to B3
"
"
"
"
268
OUT
"
"
"
"
SAB to B4
"
"
"
"
269
OUT
"
"
"
"
SAB to B5
"
"
"
"
270
OUT
"
"
"
"
SAB to B6
"
"
"
"
271
OUT
"
"
"
"
SAB to B7
"
"
"
"
272
OUT
"
"
"
"
SAB to B8
"
"
"
See footnotes at end of device type 04.
|