| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.8 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
MIL-STD-
J, K, L
Subgroup
Symbol
883
Case
2
3
4
5
6
7
9
10
11
12
13
14
Measured
Limits
Unit
method
3 1/
terminal
S3
S2
S1
S0
Cn
M
Test no.
GND
Min
Max
A0
B0
F0
F1
F2
9
tPHL9
3003
227
0.0 V
IN
0.0 V
2.7 V
2.7 V
0.0 V
0.0 V
2.7 V
OUT
GND
3.0
10.0
ns
A 0 to F 0
Tc = 25C
Fig. 4
228
"
0.0 V
"
"
"
"
"
"
OUT
"
"
"
"
A 1 to F 1
"
229
"
"
"
"
"
"
"
"
OUT
"
"
"
"
A 2 to F 2
"
230
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to F 3
"
231
IN
"
"
"
"
"
"
"
OUT
"
"
"
"
B 0 to F 0
"
232
0.0 V
"
"
"
"
"
"
"
OUT
"
"
"
"
B 1 to F 1
"
233
"
"
"
"
"
"
"
"
OUT
"
"
"
"
B 2 to F 2
"
234
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to F 3
tPLH9
"
235
"
IN
"
"
"
"
"
"
OUT
"
3.5
9.5
"
A 0 to F 0
"
236
"
0.0 V
"
"
"
"
"
"
OUT
"
"
"
"
A 1 to F 1
"
237
"
"
"
"
"
"
"
"
OUT
"
"
"
"
A 2 to F 2
"
238
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to F 3
"
239
IN
"
"
"
"
"
"
"
OUT
"
"
"
"
B 0 to F 0
"
240
0.0 V
"
"
"
"
"
"
"
OUT
"
"
"
"
B 1 to F 1
"
241
"
"
"
"
"
"
"
"
OUT
"
"
"
"
B 2 to F 2
"
242
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to F 3
tPHL10
"
243
IN
2.7 V
"
"
"
"
2.7 V
0.0 V
"
3.0
12.0
"
B 0 to F 3
"
244
2.7 V
IN
"
"
"
"
0.0 V
"
OUT
"
"
"
"
A 0 to F 1
"
245
"
"
"
"
"
"
"
"
OUT
"
"
"
"
A 0 to F 2
"
246
"
"
"
"
"
"
"
"
"
"
"
"
A 0 to F 3
"
247
"
2.7 V
"
"
"
"
"
"
"
"
"
"
A 2 to F 3
"
248
0.0 V
"
"
"
"
"
"
"
OUT
"
"
"
"
A 1 to F 2
"
249
0.0 V
"
"
"
"
"
2.7 V
"
"
"
"
"
A 1 to F 3
tPLH10
"
250
IN
"
"
"
"
"
2.7 V
"
"
4.0
"
"
B 0 to F 3
"
251
2.7 V
IN
"
"
"
"
0.0 V
"
OUT
"
"
"
"
A 0 to F 1
"
252
"
"
"
"
"
"
"
"
OUT
"
"
"
"
A 0 to F 2
"
253
"
"
"
"
"
"
"
"
"
"
"
"
A 0 to F 3
"
254
"
2.7 V
"
"
"
"
"
"
"
"
"
"
A 2 to F 3
"
255
0.0 V
"
"
"
"
"
"
"
OUT
"
"
"
"
A 1 to F 2
"
256
0.0 V
"
"
"
"
"
2.7 V
"
"
"
"
"
A 1 to F 3
See footnotes at end of device type 01.
|