| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.8 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
MIL-STD-
J, K, L
Subgroup
Symbol
883
Case
2
3
4
5
6
7
9
10
11
12
13
14
Measured
Limits
Unit
method
3 1/
terminal
S3
S2
S1
S0
Cn
M
Test no.
GND
Min
Max
A0
B0
F0
F1
F2
9
tPHL11
3003
257
2.7 V
IN
0.0 V
2.7 V
2.7 V
0.0 V
0.0 V
0.0 V
GND
2.5
10.0
ns
A 0 to G
Tc = 25C
Fig. 4
258
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to G
"
259
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to G
"
260
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to G
"
261
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to G
"
262
0.0 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to G
"
263
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to G
"
264
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to G
tPLH11
"
265
2.7 V
IN
"
"
"
"
"
"
"
3.0
9.0
"
A 0 to G
"
266
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to G
"
267
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to G
"
268
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to G
"
269
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to G
"
270
0.0 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to G
"
271
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to G
"
272
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to G
tPHL12
"
273
2.7 V
IN
"
"
"
"
"
"
"
5.0
13.0
"
A 0 to Cn + 4
"
274
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to Cn + 4
"
275
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn + 4
"
276
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn + 4
"
277
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn + 4
"
278
0.0 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn + 4
"
279
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn + 4
"
280
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn + 4
tPLH12
"
281
2.7 V
IN
"
"
"
"
"
"
"
"
14.0
"
A 0 to Cn + 4
"
282
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to Cn + 4
"
283
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to Cn + 4
"
284
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to Cn + 4
"
285
IN
"
"
"
"
"
"
"
"
"
"
"
B 0 to Cn + 4
"
286
0.0 V
"
"
"
"
"
"
"
"
"
"
"
B 1 to Cn + 4
"
287
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to Cn + 4
"
288
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to Cn + 4
See footnotes at end of device type 01.
|