TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high 2.0 V; low 0.8 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
MIL-STD-
J, K, L
Subgroup
Symbol
883
Case
2
3
4
5
6
7
9
10
11
12
13
14
Measured
Limits
Unit
method
3 1/
terminal
S3
S2
S1
S0
Cn
M
Test no.
GND
Min
Max
A0
B0
F0
F1
F2
9
tPHL13
3003
289
0.0 V
IN
0.0 V
2.7 V
2.7 V
0.0 V
0.0 V
0.0 V
GND
2.5
9.5
ns
A 0 to P
Tc = 25C
Fig. 4
290
"
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to P
"
291
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to P
"
292
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to P
"
293
IN
2.7 V
"
"
"
"
"
"
"
"
"
"
B 0 to P
"
294
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
B 1 to P
"
295
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to P
"
296
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to P
tPLH13
"
297
"
IN
"
"
"
"
"
"
"
"
8.0
"
A 0 to P
"
298
"
0.0 V
"
"
"
"
"
"
"
"
"
"
A 1 to P
"
299
"
"
"
"
"
"
"
"
"
"
"
"
A 2 to P
"
300
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to P
"
301
IN
2.7 V
"
"
"
"
"
"
"
"
"
"
B 0 to P
"
302
0.0 V
0.0 V
"
"
"
"
"
"
"
"
"
"
B 1 to P
"
303
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to P
"
304
"
"
"
"
"
"
"
"
"
"
"
"
B 3 to P
5.5
13.5
"
tPHL14
"
305
"
IN
"
"
"
"
"
"
"
A 0 to A = B
"
"
"
"
306
"
2.7 V
"
"
"
"
"
"
"
A 1 to A = B
"
"
"
"
307
"
"
"
"
"
"
"
"
"
A 2 to A = B
"
"
"
"
308
"
"
"
"
"
"
"
"
"
A 3 to A = B
"
"
"
"
309
IN
"
"
"
"
"
"
"
"
B 0 to A = B
"
"
"
"
310
0.0 V
"
"
"
"
"
"
"
"
B 1 to A = B
"
"
"
"
311
"
"
"
"
"
"
"
"
"
B 2 to A = B
"
"
"
"
312
"
"
"
"
"
"
"
"
"
B 3 to A = B
11.0
27.0
"
tPLH14
"
313
"
IN
"
"
"
"
"
"
"
A 0 to A = B
"
"
"
"
314
"
2.7 V
"
"
"
"
"
"
"
A 1 to A = B
"
"
"
"
315
"
"
"
"
"
"
"
"
"
A 2 to A = B
"
316
"
"
"
"
"
"
"
"
"
"
"
"
A 3 to A = B
"
"
"
"
317
IN
"
"
"
"
"
"
"
"
B 0 to A = B
"
"
"
"
318
0.0 V
"
"
"
"
"
"
"
"
B 1 to A = B
"
319
"
"
"
"
"
"
"
"
"
"
"
"
B 2 to A = B
"
"
"
"
320
"
"
"
"
"
"
"
"
"
B 3 to A = B
Same tests and terminal conditions as for subgroup 9, except TC = +125C and use limits from table I.
10
Same tests and terminal conditions as for subgroup 9, except TC = -55C and use limits from table I.
11
See footnotes at end of device type 01.