TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be high 2.0 V; or low 0.8 V; or open).
MIL-STD-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Limits
E and F
883
method  Cases 2 1/
Subgroup
Symbol
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Unit
and X
Test no.
J1
CP1
Q1
Q2
CP2
J2
terminal
Min
Max
GND
VCC
SD
Q
Q
SD
K 1
K 2
CD
CD
1
1
2
2
1
2
7
Func-
3014
70
A
A
B
A
B
H
L
GND
L
H
B
A
B
A
A
7/
All
Tc = +25C tional
outputs
71
A
"
"
"
A
H
L
"
L
H
A
"
"
"
A
"
tests
72
B
"
"
"
A
L
H
"
H
L
"
"
"
"
B
"
"
8/
73
A
"
"
"
A
L
H
"
H
L
"
"
"
"
A
"
"
74
"
"
"
"
B
H
L
"
L
H
B
"
"
"
"
"
"
75
"
"
"
"
A
"
"
"
"
"
A
"
"
"
"
"
"
76
"
B
A
"
B
"
"
"
"
"
B
"
A
B
"
"
"
77
"
"
A
"
A
"
"
"
"
"
A
"
A
"
"
"
"
78
"
"
B
"
"
"
"
"
"
"
"
"
B
"
"
"
"
79
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
80
"
"
"
A
"
L
H
"
H
L
"
A
"
"
"
"
"
81
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
82
"
"
"
A
"
"
"
"
"
"
"
A
"
"
"
"
"
83
"
"
A
"
"
"
"
"
"
"
"
"
A
"
"
"
"
84
"
A
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
85
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
86
"
"
"
A
"
H
L
"
L
H
"
A
"
"
"
"
"
87
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
88
"
"
"
A
"
"
"
"
"
"
"
A
"
"
"
"
"
89
"
B
"
"
B
"
"
"
"
"
B
"
"
B
"
"
"
90
"
"
"
"
A
"
"
"
"
"
A
"
"
"
"
"
"
91
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
92
"
"
"
A
"
"
"
"
"
"
"
A
"
"
"
"
"
93
B
"
"
"
"
L
H
"
H
L
"
"
"
"
B
"
"
94
A
"
"
"
"
"
"
"
"
"
"
"
"
"
A
"
"
95
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
96
"
"
"
A
"
"
"
"
"
"
"
A
"
"
"
"
"
97
"
A
"
"
"
"
"
"
"
"
"
"
"
A
"
"
"
98
"
"
B
"
"
"
"
"
"
"
"
"
B
"
"
"
"
99
"
"
"
B
"
"
"
"
"
"
"
B
"
"
"
"
"
100
"
"
"
A
"
H
L
"
L
H
"
A
"
"
"
"
"
101
"
"
"
B
"
H
L
"
L
H
"
B
"
"
"
"
"
102
"
"
"
A
"
L
H
"
H
L
"
A
"
"
"
"
"
Same tests, terminal conditions, and limits as for subgroup 7, except TC = 125C and TC = -55C.
8
9
fMAX
3003
103
2.7 V
2.7 V
0
IN
2.7 V
OUT
"
5.0 V
Q1
90
MHz
Tc = +25C
9/
Fig. 4
104
2.7 V
2.7 V
0
IN
2.7 V
OUT
"
"
"
"
Q
1
105
"
OUT
2.7 V
IN
0
2.7 V
2.7 V
"
"
"
Q 2
106
"
OUT
2.7 V
IN
0
2.7 V
2.7 V
"
Q2
"
"
tPLH1
107
2.7 V
2.7 V
0V
IN
2.7 V
OUT
"
"
CP1 to Q1
3.8
7.0
ns
tPLH1
108
"
OUT
2.7 V
IN
0V
2.7 V
2.7 V
"
CP2 to Q2
3.8
7.0
"
tPHL1
109
2.7 V
2.7 V
0
IN
2.7 V
OUT
"
"
CP1 to Q1
4.4
8.0
"
tPHL1
110
"
OUT
2.7 V
IN
0V
2.7 V
2.7 V
"
CP2 to Q2
4.4
8.0
"
tPLH2
111
2.7 V
2.7 V
0
IN
2.7 V
OUT
"
"
3.8
7.0
"
CP1 to Q
1
tPLH2
112
"
OUT
2.7 V
IN
0V
2.7 V
2.7 V
"
3.8
7.0
"
CP2 to Q
2
tPHL2
113
2.7 V
2.7 V
0
IN
2.7 V
OUT
"
"
4.4
8.0
"
CP1 to Q
1
tPHL2
114
"
OUT
2.7 V
IN
0V
2.7 V
2.7 V
"
4.4
8.0
"
CP2 to Q
2
See footnotes at end of device type 02.