| ![]() 1/
Cases 2 and X pins not referenced are N/C.
2/
Apply all voltages, then apply 3 V, 0 V, 3 V to CPX, CDX , or SDX (as required) then make measurement.
3/
IIL limits (mA) min/max values for circuits shown:
Circuits
Parameter
A
B
C
D
IIL1
-.25/-.60
-.03/-.60
-.03/-.60
0.0 mA/-0.6 mA
IIL2
-.75/-3.0
-.09/-3.0
-.12/-3.0
0.0 mA/-3.0 mA
IIL3
-1.25/-3.0
-.12/-2.40
-.12/-3.0
0.0 mA/-2.4 mA
4/
Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V.
5/
A = 2.5 V
B = 0.5 V
H ≥ 1.5 V, L ≤ 1.5 V.
6/
fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
|