| ![]() 1/
Cases 2 and X pins not referenced are N/C.
2/
Apply all voltages, then apply 3 V, 0 V, 3 V to MR , then apply 3 V, 0 V, 3 V to CP, then make measurement.
3/
IIL limits (mA) min/max values for circuits shown:
Circuits
Parameter
A
B
C
D
IIL1
-.25/-.60
-.03/-.60
-.03/-.60
0/-.30
4/
Apply all voltages, then apply 3 V, 0 V, 3 V to CP then make measurement.
5/
Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V.
6/
A = 2.5 V
B = 0.5 V
H ≥ 1.5 V
L ≤ 1.5 V
7/
fMAX shall be measured only under the conditions of initial qualification and after
process or design changes which may affect this parameter. For all other conditions,
fMAX shall be guaranteed, if not tested, to the limits specified in table III, herein.
|