TABLE III. Group A inspection for device type 09 - Continued.
Terminal conditions (pins not designated may be high 2.0 V; or low 0.8 V; or open).
MIL-STD-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Limits
E and F
883
method
Subgroup
Symbol
Cases 2
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Unit
and X 1/
Test no.
Q0
D0
D1
GND
CP
Q2
D2
D3
Q3
VCC
terminal
Min
Max
Q1
Q
Q
Q
Q
E
0
1
2
3
1
IOD
49
GND
2.5 V
GND
GND
GND
2/
GND
GND
4.5 V
Q0
60
mA
Tc = +25C
"
"
2.5 V
"
"
"
"
"
Q1
"
"
50
"
51
"
"
"
"
"
2.5 V
"
"
"
Q2
"
"
52
"
"
"
"
"
"
"
2.5 V
"
Q3
"
"
53
"
2.5 V
4.5 V
4.5 V
"
"
4.5 V
4.5 V
"
"
"
Q
0
54
"
"
"
2.5 V
"
"
"
"
"
"
"
Q
1
55
"
"
"
"
"
2.5 V
"
"
"
"
Q
2
56
"
"
"
"
"
"
"
"
"
Q
3
ICC
3005
57
"
GND
GND
"
5/
GND
GND
5.5 V
VCC
40
"
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125C and VIC tests are omitted.
2
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55C and VIC tests are omitted.
3
7
Truth
3014
58
B
L
H
B
B
H
L
GND
A
L
H
B
B
H
L
7/
All
Tc = +25C table
59
"
"
"
B
"
"
"
"
B
"
"
"
"
"
"
"
outputs
tests
60
"
"
"
A
"
"
"
"
B
"
"
"
"
"
"
"
6/
61
"
H
L
"
"
"
"
"
A
"
"
"
"
"
"
"
62
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
63
"
"
"
B
A
"
"
"
B
"
"
"
"
"
"
"
64
"
L
H
"
A
L
H
"
A
"
"
"
"
"
"
"
65
"
"
"
"
B
L
H
"
B
"
"
A
"
"
"
"
66
"
"
"
"
"
H
L
"
A
H
L
"
"
"
"
"
67
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
68
"
"
"
"
"
"
"
"
B
"
"
B
A
"
"
"
69
"
"
"
"
"
"
"
"
A
L
H
"
"
L
H
"
70
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
71
"
"
"
"
"
"
"
"
B
"
"
"
B
"
"
"
72
"
"
"
"
"
"
"
"
A
"
"
"
B
H
L
"
73
"
"
"
A
A
"
"
"
A
"
"
A
A
"
"
"
74
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
75
"
H
L
"
"
L
H
"
A
H
L
"
"
L
H
"
76
"
"
"
B
B
"
"
"
A
"
"
B
B
"
"
"
77
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
78
"
L
H
"
"
H
L
"
A
L
H
"
"
H
L
"
79
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
80
A
"
"
A
A
"
"
"
B
"
"
A
A
"
"
"
81
"
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
82
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
83
B
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
84
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
85
"
H
L
"
"
L
H
"
A
H
L
"
"
L
H
"
86
A
"
"
B
B
"
"
"
A
"
"
B
B
"
"
"
87
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
88
"
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
89
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
90
B
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
91
B
L
H
"
"
H
L
"
A
L
H
"
"
H
L
"
92
A
"
"
A
A
"
"
"
A
"
"
A
A
"
"
"
93
"
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
94
"
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
95
B
"
"
"
"
"
"
"
B
"
"
"
"
"
"
"
96
B
H
L
"
"
L
H
"
A
H
L
"
"
L
H
"
Same test and terminal conditions as for subgroup 7, except TC = +125C = -55C.
8
See footnotes at end of device type 09.