| 1/
Cases 2 and X pins not referenced are N/C.
2/
Apply all voltages, then apply 0 V, 3 V, 0 V to clock pulse, then make measurement.
3/
Apply all voltages, then apply 3 V, 0 V, 3 V to clock pulse, then make measurement.
4/
IIL limits (mA) min/max values for circuits shown:
Circuits
Parameter
A
B
C
IIL1
-.25/-.60
-.03/-.60
5/
Apply all voltages, then apply 0 V, 3 V to clock pulse, then make measurement.
6/
Inputs
A = 2.5 V
B = 0.5 V
Outputs H ≥ 1.5 V
L ≤ 1.5 V
5/
Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V
6/
fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half of the input frequency.
|