| ![]() TABLE III. Group A inspection for device type 11 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; or low ≤ 0.8 V; or open).
MIL-STD-
Subgroup
Symbol
Cases 2, R,
13
14
15
16
17
18
19
20
Measured
Limits
S, and X
883
method
Test no.
VCC
terminal
Min
Max
Unit
Q 6
Q 5
Q 4
Q 3
Q 2
Q 1
Q 0
9
fMAX
100
MHz
3003
93
OUT
5.0 V
Q
Tc = +25C 5/
0
Fig. 4
94
OUT
"
"
"
Q
1
95
OUT
"
"
"
Q
2
96
OUT
"
"
"
Q
3
97
OUT
"
"
"
Q
4
98
OUT
"
"
"
Q
5
99
OUT
"
"
"
Q
6
100
"
"
"
Q
7
tPLH2
3003
101
OUT
"
2.5
8.5
ns
CP to Q
0
Fig. 4
102
OUT
"
"
"
"
CP to Q
1
103
OUT
"
"
"
"
CP to Q
2
104
OUT
"
"
"
"
CP to Q
3
105
OUT
"
"
"
"
CP to Q
4
106
OUT
"
"
"
"
CP to Q
5
107
OUT
"
"
"
"
CP to Q
6
108
"
"
"
"
CP to Q
7
tPHL2
3003
109
OUT
"
"
"
"
CP to Q
0
Fig. 4
110
OUT
"
"
"
"
CP to Q
1
111
OUT
"
"
"
"
CP to Q
2
112
OUT
"
"
"
"
CP to Q
3
113
OUT
"
"
"
"
CP to Q
4
114
OUT
"
"
"
"
CP to Q
5
115
OUT
"
"
"
"
CP to Q
6
116
"
"
"
"
CP to Q
7
tPHZ2
3003
117
OUT
"
1.5
5.5
"
OE to Q
0
Fig. 4
118
OUT
"
"
"
"
OE to Q
1
119
OUT
"
"
"
"
OE to Q
2
120
OUT
"
"
"
"
OE to Q
3
121
OUT
"
"
"
"
OE to Q
4
122
OUT
"
"
"
"
OE to Q
5
123
OUT
"
"
"
"
OE to Q
6
124
"
"
"
"
OE to Q
7
See footnotes at end of device type 11.
|