| TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V; low ≤ 0.8 V; or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
E, F
Subgroup
Symbol
883
Cases
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2, X 1/
terminal
Test no.
S1
B1
A1
S0
A0
B0
C0
GND
C4
S3
B3
A3
S2
A2
B2
VCC
Min
Max
9
tPLH1
3003
92
GND
GND
OUT
2.7 V
GND
IN
GND
5.0 V
C0 to S0
1.5
9.5
ns
TC = 25C
Fig. 4
93
OUT
"
2.7 V
"
"
"
"
"
C0 to S1
"
"
"
"
94
"
"
"
"
"
"
OUT
2.7 V
GND
"
C0 to S2
"
"
"
"
95
"
"
"
"
"
"
OUT
GND
2.7 V
2.7 V
GND
"
C0 to S3
"
"
"
tPLH2
"
96
"
"
"
"
"
"
OUT
GND
2.7 V
2.7 V
GND
"
C0 to C4
"
7.5
"
tPLH3
"
97
OUT
"
IN
GND
"
GND
"
"
A1 to S1
"
9.5
"
"
98
OUT
IN
GND
GND
"
GND
"
"
B1 to S1
"
"
"
"
99
"
OUT
GND
IN
GND
GND
"
A3 to S3
"
"
"
"
100
"
OUT
IN
GND
GND
GND
"
B3 to S3
"
"
"
tPHL1
"
101
GND
GND
OUT
2.7 V
GND
IN
"
"
C0 to S0
"
"
"
"
102
OUT
"
2.7 V
"
"
"
"
"
C0 to S1
"
"
"
"
103
"
"
"
"
"
"
OUT
2.7 V
GND
"
C0 to S2
"
"
"
"
104
"
"
"
"
"
"
OUT
GND
2.7 V
2.7 V
GND
"
C0 to S3
"
"
"
tPHL2
"
105
"
"
"
"
"
"
OUT
GND
2.7 V
2.7 V
GND
"
C0 to C4
"
7.0
"
tPHL3
"
106
OUT
"
IN
GND
"
GND
"
"
A1 to S1
"
9.5
"
"
107
OUT
IN
GND
GND
"
GND
"
"
B1 to S1
"
"
"
"
108
"
OUT
GND
IN
GND
GND
"
A3 to S3
"
"
"
"
109
"
OUT
IN
GND
GND
GND
"
B3 to S3
"
"
"
tPLH4
"
110
IN
2.7 V
2.7 V
"
OUT
2.7 V
2.7 V
"
B2 to C4
"
7.5
"
"
111
2.7 V
IN
"
"
2.7 V
2.7 V
"
A2 to C4
"
"
"
"
112
2.7 V
2.7 V
2.7 V
"
"
IN
2.7 V
"
B4 to C4
"
"
"
"
113
"
"
2.7 V
IN
"
A4 to C4
"
"
"
tPHL4
"
114
IN
2.7 V
2.7 V
"
"
2.7 V
2.7 V
"
B2 to C4
"
7.0
"
"
115
2.7 V
IN
"
"
2.7 V
2.7 V
"
A2 to C4
"
"
"
"
116
2.7 V
2.7 V
2.7 V
"
"
IN
2.7 V
"
B4 to C4
"
"
"
"
117
"
"
2.7 V
IN
"
A4 to C4
"
"
"
10
tPLH1
1.0
14.0
"
tPLH2 Same tests and terminal conditions as for subgroup 9, except TC = 125C and limits as shown.
"
10.5
"
tPLH3
"
14.0
"
tPHL1
"
14.0
"
tPHL2
"
10.0
"
tPHL3
"
14.0
"
tPLH4
"
10.5
"
tPHL4
"
10.0
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55C.
11
1/ For cases 2 and X pins not referenced are N/C.
2/ IIL limits are as follows:
Symbol
Min/Max limits (mA) for circuit:
A
B
C
D
IIL
-0.50/-1.2
-.06/-1.2
0/-.30
IIL1
-.25/-.60
-.03/-.60
0/-.30
3/ Test numbers 60 through 91 shall be run in sequence.
4/ Inputs A = 2.5 V, B = 0.5 V
Outputs H ≥ 1.5 V, L ≤ 1.5 V.
5/ Perform subgroup 7 sequence at VCC = 4.5 V and again at VCC = 5.5 V.
.
|