| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V or low ≤ 0.8 V or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-STD-
A,B,C,D
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
Subgroup
Symbol
883
Cases 1/
X, 2
terminal
method
NC
A0
A1
A2
A3
GND
B3
B2
B1
B0
NC
EBA
VCC
Test no.
Min
Max
E AB
9
tPZL2
3003
118
IN
2.7 V
GND
OUT
0.0 V
5.0 V
2.5
8.5
ns
E AB to B0
Tc = 25C
Fig. 3
119
"
2.7 V
"
OUT
"
"
"
"
"
E AB to B1
"
120
"
2.7 V
"
OUT
"
"
"
"
"
E AB to B2
"
121
"
2.7 V
"
OUT
"
"
"
"
"
E AB to B3
tPZH1
"
122
2.7 V
OUT
"
0.0 V
IN
"
EBA to A0
"
5.7
"
"
123
"
OUT
"
0.0 V
"
"
EBA to A1
"
"
"
"
124
"
OUT
"
0.0 V
"
"
EBA to A2
"
"
"
"
125
"
OUT
"
0.0 V
"
"
EBA to A3
"
"
"
tPZH2
"
126
IN
0.0 V
"
OUT
0.0 V
"
"
"
"
E AB to B0
"
127
"
0.0 V
"
OUT
"
"
"
"
"
E AB to B1
"
128
"
0.0 V
"
OUT
"
"
"
"
"
E AB to B2
"
129
"
0.0 V
"
OUT
"
"
"
"
"
E AB to B3
10
tPLH1
1.0
6.5
"
Same tests and terminal conditions as for subgroup 9, except TC = +125C and limits as shown.
"
6.5
"
tPLH2
tPHL1
"
8.5
"
tPHL2
"
8.5
"
tPLZ1
2.0
9.5
"
tPLZ2
"
9.5
"
tPHZ1
"
7.5
"
tPHZ2
"
7.5
"
tPZL1
"
10.5
"
tPZL2
"
10.5
"
tPZH1
"
8.0
"
tPZH2
"
8.0
"
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55 C, tPLZ1 and tPLZ2 = 2.0 ns minimum and 8.5 ns maximum.
11
1/ IOZL, IIL1 limits shall be as follows:
Min/Max limits in (mA) for circuits
Test
A
B
C
IIL
-.42/-1.0
-.03/-1.0
-.03/-1.0
IOZL
-.42/-1.0
-.06/-1.6
-.03/-1.0
2/ A = 3.0 V minimum, B = 0.0 V or GND, H > 1.5 V, L < 1.5 V.
3/ Perform function swquence at VCC = 4.5 V and repeat at VCC = 5.5V.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |