| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated may be high ≥ 2.0 V or low ≤ 0.8 V or open).
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-STD-
C,D
Subgroup
Symbol
883
Case 1/
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Measured
Limits
Unit
method
2
terminal
A2
B2
GND
B3
A3
B4
A4
VCC
Test no.
A1
B1
Min
Max
Y1
Y2
Y3
Y4
1
IIL
3009
41
0.5 V
5.5 V
5.5 V
5.5 V
GND
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
A1
2/
2/
mA
Tc = 25C
"
42
5.5 V
0.5 V
5.5 V
"
"
"
"
"
"
"
B1
"
"
"
"
43
"
5.5 V
0.5 V
"
"
"
"
"
"
"
A2
"
"
"
"
44
"
"
5.5 V
0.5 V
"
"
"
"
"
"
B2
"
"
"
"
45
"
"
"
5.5 V
"
0.5 V
"
"
"
"
B3
"
"
"
"
46
"
"
"
"
"
5.5 V
0.5 V
"
"
"
A3
"
"
"
"
47
"
"
"
"
"
"
5.5 V
0.5 V
"
"
B4
"
"
"
"
48
"
"
"
"
"
"
5.5 V
5.5 V
0.5 V
"
A4
"
"
"
-100
-255
"
IOS
3011
49
0.0 V
0.0 V
0.0 V
"
"
"
"
"
"
5.5 V
"
Y1
"
"
"
50
5.5 V
5.5 V
0.0 V
0.0 V
0.0 V
"
"
"
"
"
"
Y2
"
"
"
51
"
"
5.5 V
5.5 V
"
0.0 V
0.0 V
0.0 V
"
"
"
Y3
"
"
"
52
"
"
5.5 V
5.5 V
"
5.5 V
5.5 V
0.0 V
0.0 V
0.0 V
"
Y4
ICCL
3005
53
"
"
"
"
"
5.5 V
5.5 V
5.5 V
5.5 V
"
VCC
33
"
ICCH
3005
54
0.0 V
0.0 V
0.0 V
0.0 V
"
0.0 V
0.0 V
0.0 V
0.0 V
"
VCC
6
"
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125C and VIC tests are omitted.
2
Same tests, terminal conditions and limits as for subgroup 1, except TC = 55C and VIC tests are omitted.
3
7
Func-
3014
55
B
B
H
B
B
H
GND
H
B
B
H
B
B
3/
All
Tc = 25C
tional
"
56
A
B
"
A
B
"
"
"
B
A
"
B
A
"
outputs
tests
"
57
B
A
"
B
A
"
"
"
A
B
"
A
B
"
"
4/
"
58
A
A
L
A
A
L
"
L
A
A
L
A
A
"
"
1.5
5.5
ns
9
tPLH
3003
59
IN
2.7 V
OUT
GND
5.0 V
A1 to Y1
Tc = 25C
Fig. 3
60
2.7 V
IN
OUT
"
"
"
"
"
B1 to Y1
"
"
"
"
61
IN
2.7 V
OUT
"
"
A2 to Y2
"
"
"
"
62
2.7 V
IN
OUT
"
"
B2 to Y2
"
"
"
"
63
"
OUT
IN
2.7 V
"
B3 to Y3
"
"
"
"
64
"
OUT
2.7 V
IN
"
A3 to Y3
"
"
"
"
65
"
OUT
IN
2.7 V
"
B4 to Y4
"
"
"
"
66
"
OUT
2.7 V
IN
"
A4 to Y4
1.0
4.5
"
tPHL
"
67
IN
2.7 V
OUT
"
"
A1 to Y1
"
"
"
"
68
2.7 V
IN
OUT
"
"
B1 to Y1
"
"
"
"
69
IN
2.7 V
OUT
"
"
A2 to Y2
"
"
"
"
70
2.7 V
IN
OUT
"
"
B2 to Y2
"
"
"
"
71
"
OUT
IN
2.7 V
"
B3 to Y3
"
"
"
"
72
"
OUT
2.7 V
IN
"
A3 to Y3
"
"
"
"
73
"
OUT
IN
2.7 V
"
B4 to Y4
"
"
"
"
74
"
OUT
2.7 V
IN
"
A4 to Y4
Same tests and terminal conditions as for subgroup 9, except TC = +125 C and use limits from table I.
10
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55 C.
11
See footnotes at end of device type 03.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |