MIL-M-38510/371B
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535 and shall be conducted on all devices prior to
qualification and conformance inspection. The following additional criteria shall apply:
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified in
the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be
maintained under document control by the device manufacturer's Technology Review Board (TRB) in
accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon
request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in
accordance with the intent specified in test method 1015 of MIL-STD-883.
b. Interim and final electrical test parameters shall be as specified in table II, except interim electrical parameters
test prior to burn-in is optional at the discretion of the manufacturer.
c. Additional screening for space level product shall be as specified in MIL-PRF-38535, appendix B.
TABLE II. Electrical test requirements.
Subgroups (see table III)
MIL-PRF-38535
Class S
Class B
test requirements
devices
devices
Interim electrical parameters
1
1
Final electrical test parameters
1*, 2, 3, 7*,
1*, 2, 3,
9, 10, 11
7, 9
Group A test requirements
1, 2, 3, 7, 8,
1, 2, 3, 7
9, 10, 11
9, 10, 11
Group B test when using the method 5005
1, 2, 3,
N/A
QCI option
9, 10, 11
1, 2, 3
Group C end-point electrical
parameters
1, 2, 3,
9, 10, 11
Group D end-point electrical parameters
1, 2, 3
1, 2, 3
*PDA applies to subgroup 1 for class B and subgroups 1 and 7 for class S.
4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance with MIL-
PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).
4.4.1 Group A inspection. Group A inspection shall be in accordance with table III of MIL-PRF-38535 and as follows:
a. Tests shall be as specified in table II herein.
b. Subgroups 4, 5, and 6 shall be omitted.
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II MIL-PRF-38535.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as follows:
a. End-point electrical parameters shall be as specified in table II herein.