| ![]() TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be high 2.0 V; low 0.8 V; or open).
Cases
13
14
15
16
17
18
19
20
21
22
23
24
MIL-STD-
K, L
Subgroup
Symbol
883
Case
16
17
18
19
20
21
23
24
25
26
27
28
Measured
Limits
Unit
method
3 1/
terminal
Test no.
EN2C
2Q4
2Q3
2Q2
2Q1
1Q4
1Q3
1Q2
1Q1
EN1C
VCC
Min
Max
2 CLR
1
IOZL
97
0.4 V
5.0 V
5.5 V
1Q1
-20
A
Tc = 25
98
0.4 V
"
"
1Q2
"
"
C
99
0.4 V
"
"
1Q3
"
"
100
0.4 V
"
"
1Q4
"
"
101
5.0 V
5.0 V
0.4 V
"
2Q1
"
"
102
"
"
0.4 V
"
2Q2
"
"
103
"
"
0.4 V
"
2Q3
"
"
104
"
"
0.4 V
"
2Q4
"
"
ICCH
3005
105
"
"
5.0 V
"
VCC
21
mA
ICCL
"
106
GND
"
"
"
VCC
29
"
ICCZ
"
107
GND
"
"
"
VCC
31
"
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125 and VIC tests are omitted.
2
C
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55 and VIC tests are omitted.
3
C
7
Truth
3014
108
A
H
H
H
H
H
H
H
H
H
A
5.0 V
All
6/
6/
Tc = 25
table
"
109
"
L
L
L
L
L
L
L
L
L
"
"
outputs
"
"
C
tests
"
110
"
H
H
H
H
H
H
H
H
H
"
"
"
"
"
"
111
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
112
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
113
"
L
L
L
L
L
L
L
L
L
A
"
"
"
"
"
114
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
115
"
"
"
"
"
"
"
"
"
"
B
"
"
"
"
"
116
"
H
H
H
H
H
H
H
H
H
A
"
"
"
"
"
117
B
L
L
L
L
L
L
L
L
L
A
"
"
"
"
"
118
A
H
H
H
H
H
H
H
H
H
A
"
"
"
"
"
119
A
H
H
H
H
H
H
H
H
H
B
"
"
"
"
"
120
B
L
L
L
L
L
L
L
L
L
B
"
"
"
"
"
121
A
H
H
H
H
H
H
H
H
H
A
"
"
"
"
"
122
A
L
L
L
L
L
L
L
L
L
"
"
"
"
"
"
123
A
H
H
H
H
H
H
H
H
H
"
"
"
"
"
"
124
B
L
L
L
L
L
L
L
L
L
"
"
"
"
"
Same tests, terminal conditions, and limits as for subgroup 7, except TC = +125 and -55.
8
C
C
9
tPHL1
3003
125
OUT
4.5 V
5.0 V
6
24
ns
1 CLR to 1Q1
Tc = 25
Fig. 4
126
OUT
"
"
"
"
"
C
1 CLR to 1Q2
"
127
OUT
"
"
"
"
"
1 CLR to 1Q3
"
128
OUT
"
"
"
"
"
1 CLR to 1Q4
"
129
IN
4.5 V
OUT
"
"
"
"
2 CLR to 2Q1
"
130
"
"
OUT
"
"
"
"
2 CLR to 2Q2
"
131
"
"
OUT
"
"
"
"
2 CLR to 2Q3
"
132
"
"
OUT
"
"
"
"
2 CLR to 2Q4
tPLH2
"
133
OUT
IN
"
EN1C to 1Q1
6
22
"
"
134
OUT
"
"
EN1C to 1Q2
"
"
"
"
135
OUT
"
"
EN1C to 1Q3
"
"
"
"
136
OUT
"
"
EN1C to 1Q4
"
"
"
"
137
4.5 V
IN
OUT
"
EN2C to 2Q1
"
"
"
"
138
"
"
OUT
"
EN2C to 2Q2
"
"
"
"
139
"
"
OUT
"
EN2C to 2Q3
"
"
"
"
140
"
"
OUT
"
EN2C to 2Q4
"
"
"
See footnotes at end of device type 03.
|