| TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated are open)
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
MIL-
A, B, D
STD-883
Case C
11
12
1
14
13
2
3
4
5
6
7
8
9
10
Test limits
Unit
Subgroup
Symbol
method
Measured
Min
Max
Test no.
X
B
C
D
E
F
G
GND
Y
H
I
A
x
VCC
terminal
1
3006
1
0.8 V
4.5 V
5.5 V
0.8 V
5.5 V
0.8 V
5.5 V
5.5 V
GND
-0.5 mA 0.8 V
5.5 V
Y
2.4
V
VOH
"
2
5.5 V
"
0.8 V
5.5 V
0.8 V
5.5 V
0.8 V
5.5 V
"
"
5.5 V
0.8 V
Y
"
"
TC = +25C
"
3
5.5 V
"
0.8 V
5.5 V
0.8 V
5.5 V
5.5 V
0.8 V
"
"
5.5 V
0.8 V
Y
"
"
"
4
0.32 mA -0.32 mA GND
"
GND
GND
GND
GND
GND
GND
"
"
GND
GND
Y
"
"
"
4a 1/
0.4 V
-0.32 mA GND
"
GND
GND
GND
"
"
"
"
"
"
"
Y
"
"
3007
5
2.0 V
"
2.0 V
GND
GND
"
"
"
"
20 mA
"
"
Y
0.4
"
VOL
"
6
GND
"
GND
2.0 V
2.0 V
"
"
"
"
"
"
"
Y
"
"
"
7
"
"
"
GND
GND
2.0 V
2.0 V
2.0 V
"
"
"
"
Y
"
"
"
8
"
"
"
"
"
GND
GND
GND
"
"
2.0 V
2.0 V
Y
"
"
"
9
0.47 mA
2/
"
"
"
"
"
"
"
"
"
"
GND
GND
Y
"
"
"
9a 1/
3.8 mA
1.3 V
"
"
"
"
"
"
"
"
"
"
GND
GND
Y
"
"
3009
10
0.4 V
5.5 V
5.5 V
"
A
-1.0
-2.0
mA
IIL
"
11
5.5 V
"
0.4 V
"
B
"
"
"
"
12
"
0.4 V
5.5 V
"
C
"
"
"
"
"
13
"
5.5 V
0.4 V
"
D
"
"
"
14
"
0.4 V
5.5 V
5.5 V
"
E
"
"
"
"
15
"
5.5 V
0.4 V
5.5 V
"
F
"
"
"
"
16
"
5.5 V
5.5 V
0.4 V
"
G
"
"
"
"
17
"
"
0.4 V
5.5 V
H
"
"
"
"
18
"
"
5.5 V
0.4 V
I
"
"
"
A
3010
19
2.4 V
"
GND
"
A
50
IIH1
"
20
GND
"
2.4 V
"
B
"
"
"
21
"
2.4 V
GND
"
C
"
"
"
22
"
GND
2.4 V
"
D
"
"
"
23
"
2.4 V
GND
GND
"
E
"
"
"
24
"
GND
2.4 V
GND
"
F
"
"
"
25
"
GND
GND
2.4 V
"
G
"
"
"
26
"
"
2.4 V
GND
H
"
"
"
27
"
"
GND
2.4 V
I
"
"
"
28
5.5 V
"
GND
"
A
100
"
IIH2
"
29
GND
"
5.5 V
"
B
"
"
"
30
"
5.5 V
GND
"
C
"
"
"
31
"
GND
5.5 V
"
D
"
"
"
32
"
5.5 V
GND
GND
"
E
"
"
"
33
"
GND
5.5 V
GND
"
F
"
"
"
34
"
GND
GND
5.5 V
"
G
"
"
"
35
"
"
5.5 V
GND
H
"
"
"
36
"
"
GND
5.5 V
I
"
"
See notes at end of device type 03.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |