| MIL-M-38510/505C
TABLE III. Programming characteristics for circuit A.
Limits
Symbol
Parameters
Unit
Min Typ Max
VIHH
Program-level input voltage
11.5 11.75 12.0
V
IIHH
Program-level input current Output program pulse
50
mA
Output disable, OD
50
All other inputs
10
ICCH
Program supply current
900
mA
s
TP
Program pulse width
10
20
50
td
Delay time
100
ns
---
Program pulse duty cycle
20
%
VP
Program/verify protect input voltage
18 18.5 19
V
IP
Program/verify protect input current
400
mA
s
TPP
Security fuse programming pulse width
10
40
70
Security fuse programming duty cycle
50
%
V/s
tRP
Rise time of output programming and address pulses 1
1.5
10
V/s
tRP
Rise time of security use programming pulses
1
1.5
10
VCCPP
VCC value during security fuse programming
5.75 6.0 6.25
V
VCC value for first verify
4.75 5.0 5.25
VCC value for high VCC verify
5.4 5.5 5.6
VCC value for low VCC verify
4.4 4.5 4.6
25
|