| TABLE III. Group A inspection for device type 03 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1Y
1A
1B
2Y
VEE
2A
2B
2C
3A
3B
3Y
VCC2
Min
Max
1Y
2Y
3Y
9
tTLH
3004
72
E3
OUT
LD2
IN
LD2
LD2
E2
LD2
LD2
E3
1Y
1.1
3.3
ns
Tc = 25C
"
73
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
"
1Y
"
74
"
"
LD2
"
OUT
"
IN
"
"
"
2Y
"
"
"
"
"
"
"
75
"
"
"
OUT
LD2
"
IN
"
"
"
2Y
"
76
"
"
"
LD2
"
"
IN
"
OUT
"
3Y
"
"
"
"
77
"
"
"
"
"
"
IN
OUT
LD2
"
"
"
"
3Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.0
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.0
ns
9
tTHL
3004
78
E3
OUT
LD2
IN
LD2
LD2
E2
LD2
LD2
E3
1Y
1.1
3.3
ns
Tc = 25C
OUT
IN
"
"
"
"
"
"
"
"
"
"
79
"
LD2
1Y
"
80
"
"
LD2
"
OUT
"
IN
"
"
"
2Y
"
"
"
"
81
"
"
"
OUT
LD2
"
IN
"
"
"
"
"
"
2Y
"
82
"
"
"
LD2
"
"
IN
"
OUT
"
3Y
"
"
"
"
83
"
"
"
"
"
"
IN
OUT
LD2
"
"
"
"
3Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
4.0
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
4.0
ns
9
tPLH
3003
84
E3
OUT
LD2
IN
LD2
LD2
E2
LD2
LD2
E3
1Y
1.0
2.9
ns
Tc = 25C
"
85
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
"
1Y
"
86
"
"
LD2
"
OUT
"
IN
"
"
"
2Y
"
"
"
"
87
"
"
"
OUT
LD2
"
IN
"
"
"
"
"
"
2Y
"
88
"
"
"
LD2
"
"
IN
"
OUT
"
3Y
"
"
"
"
89
"
"
"
"
"
"
IN
OUT
LD2
"
"
"
"
3Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
1.0
3.7
ns
10
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns
9
tPHL
3003
90
E3
OUT
LD2
IN
LD2
LD2
E2
LD2
LD2
E3
1Y
1.0
2.9
ns
Tc = 25C
"
91
"
LD2
OUT
IN
"
"
"
"
"
"
"
"
"
1Y
"
92
"
"
LD2
"
OUT
"
IN
"
"
"
2Y
"
"
"
"
93
"
"
"
OUT
LD2
"
IN
"
"
"
"
"
"
2Y
"
94
"
"
"
LD2
"
"
IN
"
OUT
"
3Y
"
"
"
"
95
"
"
"
"
"
"
IN
OUT
LD2
"
"
"
"
3Y
Same tests and terminal conditions as for subgroup 9, except Tc = 125C and limits as shown.
10
1.0
3.7
ns
Same tests and terminal conditions as for subgroup 9, except Tc = -55C and limits as shown.
11
1.0
3.7
ns
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |