| TABLE III. Group A inspection for device type 04 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
2A
2B
2C
2D
VEE
1A
1B
1C
3A
3B
3C
VCC2
Min
Max
1Y
2Y
3Y
1
VOTL
36
GND
LD1
LD1
E1
VITH
LD1
GND
-1.600
V
1Y
Tc = 25C
37
"
"
"
VITH
"
"
"
"
"
2Y
38
"
"
"
VITH
"
"
"
"
"
2Y
39
"
"
"
VITH
"
"
"
"
"
2Y
40
"
"
"
VITH
"
"
"
"
"
2Y
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.525
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.635
V
1
IEE
3005
41
GND
E1
GND
VEE
-21
mA
Tc = 25C
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-24
mA
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-24
mA
A
1
IIH1
3010
42
GND
E1
VIH1
GND
3A
265
Tc = 25C
"
3B
"
"
"
43
"
"
VIH1
"
44
"
"
VIH1
"
3C
"
"
"
45
"
"
VIH1
"
1A
"
"
"
46
"
"
VIH1
"
1B
"
"
"
47
"
"
VIH1
"
1C
"
"
"
48
"
VIH1
"
"
2A
"
"
"
49
"
VIH1
"
"
2B
"
"
"
50
"
VIH1
"
"
2C
"
"
"
51
"
VIH1
"
"
2D
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
450
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
450
A
1
IIL
3009
52
GND
E1
VIL1
GND
3A
0.5
Tc = 25C
"
53
"
"
VIL1
"
3B
"
"
"
54
"
"
VIL1
"
3C
"
"
"
55
"
"
VIL1
"
1A
"
"
"
56
"
"
VIL1
"
1B
"
"
"
57
"
"
VIL1
"
1C
"
"
"
58
"
VIL1
"
"
2A
"
"
"
59
"
VIL1
"
"
2B
"
"
"
60
"
VIL1
"
"
2C
"
"
"
61
"
VIL1
"
"
2D
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
0.3
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
0.5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |