TABLE III. Group A inspection for device type 05 - Continued.
For terminal conditions see table IIIA. Terminals not designated are open.
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no.
VCC1
1Y
1A
1B
2B
VEE
2A
2Y
3Y
3A
3B
VCC2
Min
Max
1Y
2Y
3Y
1
VOTH
41
GND
LD1
LD1
E1
VITL
LD1
LD1
LD1
LD1
GND
-0.950
V
2Y
Tc = 25C
42
"
"
"
VITL
"
"
"
"
"
"
"
"
2Y
43
"
"
"
"
"
"
"
"
VITL
VITL
"
"
"
3Y
44
"
"
"
VITL
VITL
"
"
"
"
"
"
"
"
1Y
45
"
"
"
VITL
"
VITL
"
"
"
"
"
"
"
2Y
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-0.845
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.100
V
1
VOTL
46
GND
LD1
LD1
E1
LD1
LD1
LD1
LD1
VITH
GND
-1.600
V
3Y
Tc = 25C
47
"
"
"
"
"
"
"
"
VITH
"
"
"
3Y
48
"
"
"
VITH
"
"
"
"
"
"
"
"
1Y
49
"
"
"
VITH
"
"
"
"
"
"
"
"
1Y
"
"
50
"
"
"
"
VITH
"
"
"
"
"
2Y
51
"
"
"
VITH
"
"
"
"
"
"
"
"
2Y
52
"
"
"
"
"
"
"
"
VITL
"
3Y
"
"
53
"
"
"
"
"
"
"
"
VITL
"
3Y
"
"
54
"
"
"
VITL
"
"
"
"
"
"
1Y
"
"
55
"
"
"
VITL
"
"
"
"
"
"
1Y
"
"
56
"
"
"
"
VITL
"
"
"
"
"
2Y
"
"
57
"
"
"
VITL
"
"
"
"
"
"
2Y
"
"
58
"
"
"
"
"
"
"
"
VITH
VITH
"
3Y
"
"
59
"
"
"
VITH
VITH
"
"
"
"
"
"
1Y
"
"
60
"
"
"
VITH
"
VITH
"
"
"
"
"
2Y
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.525
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.635
V
1
IEE
3005
61
GND
VIH1
VIH1
E1
VIH1
GND
VEE
-28
mA
Tc = 25C
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
-31
mA
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-31
mA
A
1
IIH1
3010
62
GND
VIH1
E1
GND
1A
265
Tc = 25C
63
"
"
VIH1
"
2A
"
"
64
"
"
VIH1
"
3A
"
"
65
"
VIH1
VIH1
"
"
1A
"
"
66
"
VIH1
"
VIH1
"
2A
"
"
67
"
"
VIH1
VIH1
"
3A
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
450
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
450
A
1
IIH2
3010
68
GND
VIH1
E1
GND
1B
220
Tc = 25C
69
"
VIH1
"
"
2B
"
"
70
"
"
VIH1
"
3B
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
375
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
375
A
1
IIL
3009
71
GND
VIL1
E1
GND
1A
0.5
Tc = 25C
"
72
"
VIL1
"
"
1B
"
"
"
73
"
VIL1
"
"
2B
"
"
"
74
"
"
VIL1
"
2A
"
"
"
75
"
"
VIL1
"
3A
"
"
"
76
"
"
VIL1
"
3B
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
0.3
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
0.5