4.3 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-38535.
4.4 Technology Conformance inspection (TCI). Technology conformance inspection shall be in accordance with
MIL-PRF-38535 and herein for groups A, B, C, and D inspections (see 4.4.1 through 4.4.4).
4.4.1 Group A inspection. Group A inspection shall be in accordance with table III of MIL-PRF-38535 and as
follows:
a. Tests shall be as specified in table II herein.
b. Subgroups 4, 5, 6, 7, and 8 shall be omitted.
4.4.2 Group B inspection. Group B inspection shall be in accordance with table II MIL-PRF-38535.
4.4.3 Group C inspection. Group C inspection shall be in accordance with table IV of MIL-PRF-38535 and as
follows:
a. End-point electrical parameters shall be as specified in table II herein.
b. The steady-state life test duration, test condition, and test temperature, or approved alternatives shall be
as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test
circuit shall be maintained under document control by the device manufacturer's Technology Review
Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or
preparing activity upon request. The test circuit shall specify the inputs, outputs, biases, and power
dissipation, as applicable, in accordance with the intent specified in test method 1005 of MIL-STD-883.
4.4.4 Group D inspection. Group D inspection shall be in accordance with table V of MIL-PRF-38535. End-point
electrical parameters shall be as specified in table II herein.
4.5 Methods of inspection. Methods of inspection shall be as specified and as follows:
4.5.1 Voltage and current. All voltages given are referenced to the microcircuit ground terminal. Currents given
are conventional and positive when flowing into the referenced terminal.
TABLE IIIA. Test conditions for all devices, group A inspection
Symbol
VIH1
VIL1
VIH2
VIL2
VITL
VITH
A
B
C
D
E
t ≥ 1s
t ≥ 1s
t ≥ 1s
(V)
(V)
(V)
(V)
(V)
(V)
TC = 25C
100Ω
100Ω
-.780
-1.850
+1.11
+0.31
-1.475
-1.105
VIH
VIH
VIH
to
to
VIL
VITH
VITL
-2.0 V
GND
TC = 125C -.630
100Ω
100Ω
-1.82
+1.24
+0.36
-1.40
-1.0
VIH
VIH
VIH
to
to
VIL
VITH
VITL
-2.0 V
GND
TC = -55C -.880
100Ω
100Ω
-1.92
+1.01
+0.28
-1.51
-1.255
VIH
VIH
VIH
to
to
VIL
VITH
VITL
-2.0 V
GND