| MIL-M-38510/61C
GENERATOR CHARACTERISTICS
VIH2
TC
VIL2
10 mV
10 mV
25C
+1.11 V +0.31 V
125C
+1.24 V +0.36 V
-55C
+1.01 V +0.28 V
RL
2 = 50Ω 5%
SCOPE INPUT = 50Ω to GND
CL (test jig) ≤ 5 pF
FREQ (IN)
FREQ. (OUT) =
2
FMAX IS HIGHEST INPUT FREQUENCY AT WHICH DEVICE CEASES TO TOGGLE
NOTES:
1. Perform test in accordance with test table; each output is tested separately.
2. All input and output cables are equal lengths of 50 ohm coaxial cables. Wire length should be ≤ .250
(6.35 mm) from tp in to input pin and tp out to output pin.
3. Outputs not under test connected to a 100 ohm resistor to ground.
4. Note that observed pulse amplitude is attenuated by one half.
FIGURE 10. FMAX test circuit for device type 04.
21
|