| TABLE III. Group A inspection for device type 03 - Continued.
For terminal conditions see table IIIA
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
Test no. VCC1
1Q
2Q
3Q
1D
2D
3D
VEE
CLK
4D
5D
6D
4Q
5Q
6Q
VCC2
Min
Max
1
Precond
43
GND
A
A
A
VIH1
-5.2 V
C
A
A
A
GND
-1.6
V
Tc = 25C
VOTL
44
"
"
"
"
VITL
"
C
"
"
"
"
1Q
"
"
VOTL
45
"
"
"
"
VIH1
"
D
"
"
"
"
1Q
"
"
Precond
46
"
"
"
"
VIH1
"
C
"
"
"
"
"
"
VOTL
47
"
"
"
"
VIL1
"
E
"
"
"
"
1Q
"
"
Precond
48
VIH1
C
"
"
"
"
"
"
VOTL
49
"
"
"
"
VITL
"
C
"
"
"
"
2Q
"
"
VOTL
50
"
"
"
"
VIH1
"
D
"
"
"
"
2Q
"
"
Precond
51
"
"
"
"
VIH1
"
C
"
"
"
"
"
"
VOTL
52
"
"
"
"
VIL1
"
E
"
"
"
"
2Q
"
"
Precond
53
"
"
"
"
VIH1
"
C
"
"
"
"
"
"
VOTL
54
"
"
"
"
VITL
"
C
"
"
"
"
3Q
"
"
VOTL
55
"
"
"
"
VIH1
"
D
"
"
"
"
3Q
"
"
Precond
56
"
"
"
"
VIH1
"
C
"
"
"
"
"
"
VOTL
57
"
"
"
"
VIL1
"
E
"
"
"
"
3Q
"
"
Precond
58
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
59
"
"
"
"
"
C
VITL
"
"
"
"
4Q
"
"
VOTL
60
"
"
"
"
"
D
VIH1
"
"
"
"
4Q
"
"
Precond
61
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
62
"
"
"
"
"
E
VIL1
"
"
"
"
4Q
"
"
Precond
63
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
64
"
"
"
"
"
C
VITL
"
"
"
"
5Q
"
"
VOTL
65
"
"
"
"
"
D
VIH1
"
"
"
"
5Q
"
"
Precond
66
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
67
"
"
"
"
"
E
VIL1
"
"
"
"
5Q
"
"
Precond
68
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
69
"
"
"
"
"
C
VITL
"
"
"
"
6Q
"
"
VOTL
70
"
"
"
"
"
D
VIH1
"
"
"
"
6Q
"
"
Precond
71
"
"
"
"
"
C
VIH1
"
"
"
"
"
"
VOTL
72
"
"
"
"
"
E
VIL1
"
"
"
"
6Q
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.525
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.635
V
1
IEE
3005
73
GND
-5.2 V
GND
VEE
-110
mA
Tc = 25C
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-121
mA
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-121
mA
A
1
IIH1
3010
74
GND
VIH1
-5.2 V
GND
1D
220
Tc = 25C
75
"
VIH1
"
"
2D
"
"
76
"
VIH1
"
"
3D
"
"
77
"
"
VIH1
"
4D
"
"
78
"
"
VIH1
"
5D
"
"
79
"
"
VIH1
"
6D
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
375
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
375
A
1
IIH2
3010
80
GND
-5.2 V
VIH1
GND
CLK
310
Tc = 25C
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
527
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
527
A
1
IIL
3009
81
GND
VIL1
-5.2 V
GND
1D
0.5
Tc = 25C
82
"
VIL1
"
"
2D
"
"
83
"
VIL1
"
"
3D
"
"
84
"
"
VIL1
"
4D
"
"
85
"
"
VIL1
"
5D
"
"
86
"
"
VIL1
"
6D
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
A
2
0.3
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
A
3
0.5
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |