| TABLE III. Group A inspection for device type 04.
For terminal conditions see table IIIA
Case E
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-STD-
Case F
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
Subgroup
Symbol
883
Case
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Measured
Limits
Unit
method
2
terminal
1CLR
1P/S
1K
1J
VEE
2Q
VCC2
Test no.
VCC1
1Q
C
2J
2K
2P/S
2CLR
Min
Max
1Q
2Q
1
VOH
3006
1
GND
A
A
VIH1
-5.2 V
A
A
GND
-.93
-.78
V
1Q
Tc = 25C
"
2
"
"
"
VIH1
"
"
"
"
1Q
"
"
"
"
"
"
"
3
"
"
"
"
VIH1
"
"
"
2Q
"
4
"
"
"
"
VIH1
"
"
"
2Q
"
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-.825
-.63
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.08
-.88
V
-1.85
-1.62
V
1
VOL
3007
5
GND
A
A
VIH1
-5.2 V
A
A
GND
1Q
Tc = 25C
"
6
"
"
"
VIH1
"
"
"
"
1Q
"
"
"
"
7
"
"
"
"
VIH1
"
"
"
"
"
"
2Q
"
8
"
"
"
"
VIH1
"
"
"
2Q
"
"
"
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-1.82
-1.545
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.92
-1.655
V
1
VOTH
9
GND
A
A
VIL1
VIH1
VIL1
VIL1
-5.2 V
VIL1
VIL1
VIL1
VIH1
VIL1
A
A
GND
1Q
-.95
V
Tc = 25C
10
"
"
"
"
"
"
"
"
"
"
"
VIH1
VIL1
"
"
"
2Q
"
"
11
"
"
"
VITH
VIL1
"
"
"
"
"
"
VIL1
VITH
"
"
"
"
"
1Q
12
"
"
"
VITH
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
2Q
13
"
"
"
VIL1
"
"
"
"
"
"
"
"
VIL1
"
"
"
"
"
1Q
14
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
15
"
"
"
"
VITL
"
"
"
"
"
"
VITL
"
"
"
"
"
"
1Q
16
"
"
"
"
VITL
"
"
"
"
"
"
VITL
"
"
"
"
"
"
2Q
17
"
"
"
"
VITH
"
"
"
"
"
"
VITH
"
"
"
"
1Q
"
"
18
"
"
"
"
VITH
"
"
"
"
"
"
VITH
"
"
"
"
2Q
"
"
19
"
"
"
"
VIL1
"
"
"
"
"
"
VIL1
"
"
"
"
1Q
"
"
20
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
"
"
21
"
"
"
VITL
"
"
"
"
"
"
"
"
VITL
"
"
"
1Q
"
"
22
"
"
"
VITL
"
"
"
"
"
"
"
"
VITL
"
"
"
2Q
"
"
23
"
"
"
VITH
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
1Q
24
"
"
"
VITH
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
2Q
25
"
"
"
VIL1
"
VITH
"
"
"
"
VITH
"
VIL1
"
"
"
"
"
1Q
26
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
27
"
"
"
"
"
"
"
"
VITL
"
"
"
"
"
"
"
"
"
1Q
28
"
"
"
"
"
"
"
"
VITL
"
"
"
"
"
"
"
"
"
2Q
29
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
"
1Q
"
"
30
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
"
"
2Q
"
"
31
"
"
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
"
1Q
"
"
32
"
"
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
"
2Q
"
"
33
"
"
"
"
"
VIL1
"
"
"
"
VIL1
"
"
"
"
"
1Q
"
"
34
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
"
"
35
"
"
"
"
"
"
VITH
"
"
VITH
"
"
"
"
"
"
1Q
"
"
36
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
"
"
37
"
"
"
"
"
"
"
"
VITL
"
"
"
"
"
"
"
1Q
"
"
38
"
"
"
"
"
"
"
"
VITL
"
"
"
"
"
"
"
2Q
"
"
39
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
"
"
1Q
"
"
40
"
"
"
"
"
"
"
"
VITH
"
"
"
"
"
"
"
"
"
2Q
41
"
"
"
"
"
"
"
"
VIL1
"
"
"
"
"
"
"
"
"
1Q
42
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
2Q
43
"
"
"
"
"
"
VITL
"
"
VITL
"
"
"
"
"
"
"
"
1Q
44
"
"
"
"
"
"
VITL
"
"
VITL
"
"
"
"
"
"
"
"
2Q
Same tests and terminal conditions as for subgroup 1, except Tc = 125C and limits as shown.
2
-.845
V
Same tests and terminal conditions as for subgroup 1, except Tc = -55C and limits as shown.
3
-1.1
V
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |