| ![]() MIL-M-38510/62B
Generator characteristic:
TA
VIH2
VIL2
(10 mV)
(10 mV)
25C
+1.11 V
+0.31 V
125C
+1.24 V
+0.36 V
-55C
+1.01 V
+0.28 V
tP = 40 ns 1 ns
ZOUT = 50 Ω
tTHL = 2.0 ns (20% - 80%) 0.2 ns
tTLH = 2.0 ns (20% - 80%) 0.2 ns
RRR = 1.0 MHz .05 MHz
NOTES:
1/ Perform test in accordance with test table; each output is tested separately.
2/ All input and output cables to the scope are equal lengths of 50 Ω coaxial cables. Wire length should be
≤ 0.250 (6.35 mm) from tPIN to input pin and tPOUT to output pin.
3/ Output not under test connected to a 100 Ω resistor to ground.
4/ Applies to gate 4 only.
FIGURE 3. Switching time test circuit and waveforms.
11
|