| MIL-M-38510/650B
TABLE II. Electrical test requirements.
MIL-PRF-38535
Line
Class S or V device 1/
Class B or Q device 1/
no.
test requirements
Table IV
Ref.
Table III
Ref.
Table
Table IV
delta
par.
subgroups
par.
III
delta
Subgroups
2/
3/
limits
2/
3/
1
Interim electrical
1
1
parameters
2
Static burn-in I
4.2c
Req'd
Not req'd
(method 1015)
4.5.2
Ć
3
Same as line 1
1
4
Static burn-in II
4.2c
Req'd
4.2c
4/
(method 1015)
4.5.2
4.5.2
req'd
Ć
Ć
5
Same as line 1
4.2e
1*
4.2e
1*
6
Dynamic burn-in
4.2c
Req'd
Not req'd
(method 1015)
4.5.2
Ć
7
Same as line 1
4.2e
1
8
Final electrical
1, 2, 3, 9
1*, 2, 9
4/
parameters
9
Group A test
4.4.1
1, 2, 3, 4,
4.4.1
1, 2, 3, 4, 9,
requirements
9, 10, 11
10, 11
Ć
10
Group B test
1, 2, 3, 9,
1
4.4.2
when using
10, 11
method 5005
QCI option
Ć
11
Group C end-
4.4.3
1, 2
point electrical
parameters
12
Group D end-
1, 2, 3
4.4.4
1, 2
4.4.4
point electrical
parameters
1/
Blank spaces indicate tests are not applicable.
2/
* indicates PDA applies to subgroup 1 (see 4.2.1).
Ć indicates delta limits shall be required only on table III subgroup 1, where specified, and the delta values shall be
3/
computed with reference to the previous interim electrical parameters.
4/
The device manufacturer may at his option either complete subgroup 1 electrical parameter measurements,
including delta measurements, within 96 hours after burn-in completion (removal of bias); or may complete
subgroup 1 electrical measurements without delta measurements within 24 hours after burn-in completion (removal
of bias).