| MIL-M-38510/653B
Class S device 1/
Line
MIL-PRF-38535
Class B device 1/
no.
test requirements
Table IV
Ref.
Table III
Table IV
Ref.
Table III
subgroups delta limits
par.
subgroups
delta
par.
2/
3/
2/
3/
1
Interim electrical
1
1
parameters
2
Static burn-in I
4.2c
Req'd
Not req'd
(method 1015)
4.5.2
Ć
3
Same as line 1
1*
4
Static burn-in II
4.2c
Req'd
4.2c
4/
(method 1015)
4.5.2
4.5.2
req'd
Ć
Ć
5
Same as line 1
4.2e
1*
4.2e
1*
6
Dynamic burn-in
4.2c
Req'd
Not req'd
(method 1015)
4.5.2
Ć
7
Same as line 1
4.2e
1
8
Final electrical
* 1, 2, 3, 7, 8,
1*, 2, 7, 9
parameters
9
4/
9
Group A test
4.4.1
1, 2, 3, 4, 7,
4.4.1
1, 2, 3, 4, 7, 8,
requirements
8, 9, 10, 11
9, 10, 11
Ć
10
Group B test
4.4.2
1, 2, 3, 7, 8,
when using
9, 10, 11
method 5005
QCI option
Ć
Ć
11
Group C end-
4.4.2
1, 2, 3, 7, 8,
4.4.3
1, 2
point electrical
9, 10, 11
parameters
12
Group D end-
4.4.4
1, 2, 3
4.4.4
1, 2
point electrical
parameters
1/ Blank spaces indicate tests are not applicable.
2/ * indicates PDA applies to subgroup 1 (see 4.2.1).
Ć indicates delta limits shall be required only on table III subgroup 1, where specified, and the delta values shall
3/
be computed with reference to the previous interim electrical parameters.
4/ The device manufacturer may, at his option, either complete subgroup 1 electrical parameter measurements,
including delta measurements, within 96 hours after burn-in completion (removal of bias); or may complete
subgroup 1 electrical measurements without delta measurements within 24 hours after burn-in completion
(removal of bias).