NOTES:
1. Clock input pulse characteristics: tr = tf ≤ 6 ns; tp (clock) ≤ 30 ns.
2. J or K input pulse characteristics: tr = tf ≤ 6 ns; tp (J or K) ≤ 38 ns; thold ≤ 8 ns; tsetup ≤ 30 ns.
3. The clock input characteristics for fMAX are as follows: tr = tf ≤ 6 ns; tp (clock) ≤ 24 ns; PRR ≥ 21 MHz.
4. CL = 50 pF 10 % (including test jig and probe capacitance).
5. Voltage measurements are to be made with respect to network ground terminal.
6. tTLH = tTLH2 tTLH1 ; tTHL = tTHL2 - tTHL1.
FIGURE 3. Synchronous switching test circuit and waveforms (device type 05) - Continued.