| TABLE III. Group A inspection for device type 04 Continued.
Symbol
MIL- Case
Terminal conditions 1/
Measured
Test limits 8/
Unit
STD-
2
terminal
Subgroup 9 Subgroup 10 Subgroup 11
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
883 Cases
TC = +25C TC = +125C TC = -55C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
method E,F
Min
Max
Min
Max
Min
Max
Test
1CLR
1J
1K
1CLK 1PRE
1Q
1Q
GND
2Q
2Q
2PRE 2CLK
2K
2J
2CLR VCC
no.
1PRE to 1Q
tPLH2
3003
129
4.5V 4.5V GND GND
IN
OUT
GND
4.5V
6
41
6
54
6
41
ns
1CLR to 1Q
(Fig. 3) 130
IN
4.5V GND GND 4.5V
OUT
"
"
"
"
"
"
"
"
"
2CLR to 2Q
7/
131
"
OUT
4.5V GND GND 4.5V
IN
"
"
"
"
"
"
"
"
2PRE to 2Q
132
"
OUT
IN
GND GND 4.5V 4.5V
"
"
"
"
"
"
"
"
3004
133
4.5V
IN GND
IN
4.5V
OUT
"
tTHL
"
1Q
3
15
3
20
3
15
"
(Fig. 3) 134
4.5V 4.5V IN
IN
4.5V
OUT
"
"
1Q
"
"
"
"
"
"
"
7/
135
"
OUT
4.5V
IN
4.5V IN
4.5V
"
2Q
"
"
"
"
"
"
"
136
"
OUT
4.5V
IN
IN GND 4.5V
"
2Q
"
"
"
"
"
"
"
3004
137
4.5V
IN 4.5V
IN
4.5V
OUT
"
tTLH
"
1Q
"
"
"
"
"
"
"
(Fig. 3) 138
4.5V GND IN
IN
4.5V
OUT
"
"
1Q
"
"
"
"
"
"
"
7/
139
"
OUT
4.5V
IN
GND IN
4.5V
"
2Q
"
"
"
"
"
"
"
140
"
OUT
4.5V
IN
IN 4.5V 4.5V
"
2Q
"
"
"
"
"
"
"
See footnotes at end of table.
|