| TABLE III. Group A inspection for device type 07.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open)
MIL-
Cases A,
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
Subgroup
Symbol
STD-883
B, C, D
Measured
Unit
method
Min
Max
terminal
Test no.
1A
1B
NC
1C
1D
1Y
GND
2Y
2A
2B
NC
2C
2D
VCC
1
3007
1
2.0 V
2.0 V
GND
2.0 V
2.0 V
20 mA
GND
GND
GND
GND
GND
GND
4.5 V
1Y
0.2
0.5
V
VOL
3007
2
GND
GND
"
GND
GND
"
20 mA
2.0 V
2.0 V
"
2.0 V
2.0 V
"
2Y
0.2
0.5
V
TC = 25C
3
GND
5.5 V
"
5.5 V
5.5 V
5.5 V
"
5.5 V
5.5 V
"
5.5 V
5.5 V
"
1Y
250
A
ICEX
4
5.5 V
GND
"
5.5 V
"
"
"
"
"
"
"
"
"
1Y
"
"
5
"
5.5 V
"
GND
"
"
"
"
"
"
"
"
"
1Y
"
"
6
"
"
"
5.5 V
GND
"
"
"
"
"
"
"
"
1Y
"
"
7
"
"
"
"
5.5 V
"
5.5 V
GND
"
"
"
"
"
2Y
"
"
8
"
"
"
"
"
"
"
5.5 V
GND
"
"
"
"
2Y
"
"
9
"
"
"
"
"
"
"
"
5.5 V
"
GND
"
"
2Y
"
"
10
"
"
"
"
"
"
"
"
5.5 V
"
5.5 V
GND
"
2Y
"
"
11
-18 mA
"
"
"
"
1A
-1.2
V
VIC
12
-18 mA
"
"
"
"
1B
"
"
13
"
-18 mA
"
"
"
1C
"
"
"
14
"
-18 mA
"
"
"
1D
"
"
15
"
"
-18 mA
"
"
2A
"
16
"
"
-18 mA
"
"
2B
"
"
17
"
"
"
-18 mA
"
2C
"
"
18
"
"
"
-18 mA
"
2D
"
"
3010
19
2.7 V
GND
"
GND
GND
"
GND
GND
"
GND
GND
5.5 V
1A
50
A
IIH1
"
20
GND
2.7 V
"
GND
"
"
"
"
"
"
"
"
1B
"
"
"
21
"
GND
"
2.7 V
"
"
"
"
"
"
"
"
1C
"
"
"
22
"
"
"
GND
2.7 V
"
"
"
"
"
"
"
1D
"
"
"
23
"
"
"
"
GND
"
2.7 V
"
"
"
"
"
2A
"
"
"
24
"
"
"
"
"
"
GND
2.7 V
"
"
"
"
2B
"
"
"
25
"
"
"
"
"
"
"
GND
"
2.7 V
"
"
2C
"
"
"
26
"
"
"
"
"
"
"
"
"
GND
2.7 V
"
2D
"
"
"
27
5.5 V
"
"
"
"
"
"
"
"
"
GND
"
1A
1
mA
IIH2
"
28
GND
5.5 V
"
"
"
"
"
"
"
"
"
"
1B
"
"
"
29
"
GND
"
5.5 V
"
"
"
"
"
"
"
"
1C
"
"
"
30
"
"
"
GND
5.5 V
"
"
"
"
"
"
"
1D
"
"
"
31
"
"
"
"
GND
"
5.5 V
"
"
"
"
"
2A
"
"
"
32
"
"
"
"
"
"
GND
5.5 V
"
"
"
"
2B
"
"
"
33
"
"
"
"
"
"
"
GND
"
5.5 V
"
"
2C
"
"
"
34
"
"
"
"
"
"
"
GND
"
GND
5.5 V
"
2D
"
"
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |