| TABLE III. Group A inspection for device type 08.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open)
MIL-
Cases A,
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
Subgroup
Symbol
STD-883
B, C, D
Measured
Unit
method
Min
Max
terminal
Test no.
A
B
C
D
E
F
GND
Y
NC
NC
G
H
NC
VCC
1
3006
1
0.8 V
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
GND
-1 mA
GND
GND
5.5 V
5.5 V
GND
4.5 V
Y
2.5
V
VOH
"
2
5.5 V
0.8 V
5.5 V
"
"
"
"
"
"
"
"
"
"
"
"
"
"
TC = 25C
"
3
"
5.5 V
0.8 V
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
4
"
"
5.5 V
0.8 V
"
"
"
"
"
"
"
"
"
"
"
"
"
"
5
"
"
"
5.5 V
0.8 V
"
"
"
"
"
"
"
"
"
"
"
"
"
6
"
"
"
"
5.5 V
0.8 V
"
"
"
"
"
"
"
"
"
"
"
"
7
"
"
"
"
"
5.5 V
"
"
"
"
0.8 V
"
"
"
"
"
"
"
8
"
"
"
"
"
5.5 V
"
"
"
"
5.5 V
0.8 V
"
"
"
"
"
3007
9
2.0 V
2.0 V
2.0 V
2.0 V
2.0 V
2.0 V
"
20 mA
"
"
2.0 V
2.0 V
"
"
"
0.2
0.5
"
VOL
10
-18 mA
"
"
"
"
"
A
-1.2
"
VIC
"
11
-18 mA
"
"
"
"
"
B
"
12
-18 mA
"
"
"
"
"
C
"
"
13
-18 mA
"
"
"
"
"
D
"
"
14
-18 mA
"
"
"
"
"
E
"
"
15
-18 mA
"
"
"
"
"
F
"
"
"
16
"
"
"
-18 mA
"
"
G
"
17
"
"
"
-18 mA
"
"
H
"
"
3010
18
2.7 V
GND
GND
GND
GND
GND
"
"
"
GND
GND
"
5.5 V
A
50
A
IIH1
"
19
GND
2.7 V
GND
"
"
"
"
"
"
"
"
"
"
B
"
"
"
20
"
GND
2.7 V
"
"
"
"
"
"
"
"
"
"
C
"
"
"
21
"
"
GND
2.7 V
"
"
"
"
"
"
"
"
"
D
"
"
"
22
"
"
"
GND
2.7 V
"
"
"
"
"
"
"
"
E
"
"
"
23
"
"
"
"
GND
2.7 V
"
"
"
"
"
"
"
F
"
"
"
24
"
"
"
"
"
GND
"
"
"
2.7 V
"
"
"
G
"
"
"
25
"
"
"
"
"
"
"
"
"
GND
2.7 V
"
"
H
"
"
"
26
5.5 V
"
"
"
"
"
"
"
"
"
GND
"
"
A
1
mA
IIH2
"
27
GND
5.5 V
"
"
"
"
"
"
"
"
"
"
"
B
"
"
"
28
"
GND
5.5 V
"
"
"
"
"
"
"
"
"
"
C
"
"
"
29
"
"
GND
5.5 V
"
"
"
"
"
"
"
"
"
D
"
"
"
30
"
"
"
GND
5.5 V
"
"
"
"
"
"
"
"
E
"
"
"
31
"
"
"
"
GND
5.5 V
"
"
"
"
"
"
"
F
"
"
"
32
"
"
"
"
"
GND
"
"
"
5.5 V
"
"
"
G
"
"
"
33
"
"
"
"
"
GND
"
"
"
GND
5.5 V
"
"
H
"
"
|