| MIL-M-38510/71D
TABLE I. Electrical performance characteristics - Continued.
Limits
Conditions 1/
Device
Units
Test
Symbol
Min
Max
-55C ≤ TC ≤ +125C
type
VCC = 5.0 V;
06
55
MHz
Maximum clock frequency
fMAX
5/
RL = 280 Ω;
CL = 50 pF
2.0
17.0
ns
Propagation delay time,
tPLH1
low-to-high level, clock to Q or Q
Propagation delay time,
2.0
23.0
ns
tPHL1
high-to-low level, clock to Q or Q
Propagation delay time,
2.0
17.0
ns
tPLH2
low-to-high level, clock to Q,
clear inactive
Propagation delay time,
2.0
29.0
ns
tPHL2
high-to-low level, clear to Q
Propagation delay time,
2.0
20.0
ns
tPLH3
low-to-high level, clear to Q
2
23.0
ns
Propagation delay time,
tPHL3
high-to-low level, clock to Q,
clear inactive
1/ Complete terminal conditions shall be as specified in table III.
2/ At TC = +125C, VIL = 0.7 V, VOL maximum = 0.45 V.
3/ Not more than one output should be shorted at a time, duration of short circuit not to exceed 5 seconds.
4/ With all outputs open, ICC is measured with the Q and Q outputs high in turn. At the time of the measurement,
the clock input is grounded.
5/ With all outputs open and 5.5 applied to all data and clear inputs, ICC is measured after a momentary ground,
then 5.5 V is applied to clock.
6/ fMAX, minimum limit specified is the frequency of the input pulse. The output frequency shall be one-half
of the input frequency.