| TABLE III. Group A inspection for device type 01.
Terminal conditions (pins not designated may be high > 2.0 V, low < 0.8 V, or open).
Cases X, 2 1/
2
3
4
6
8
9
10
12
13
14
16
18
19
20
Cases A,
MIL-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Test limits
Subgroup
B,C,D
Symbol STD-883
Measured
Unit
method
Min
Max
terminal
GND
Q2
PRE 2
CLK 2
D2
CLR 2
Test no.
CLR 1
D1
CLK 1
PRE 1
Q1
Q1
Q2
VCC
1
3006
1
2.0 V
5.5 V
C 2/
0.8 V
-1 mA
GND
4.5 V
2.5
V
Q1
VOH
"
"
"
2
0.8 V
5.5 V
C
2.0 V
-1 mA
"
"
Q1
TC = +25C
"
3
"
-1 mA
0.8 V
C
5.5 V
2.0 V
"
"
"
Q2
"
"
"
4
"
-1 mA
2.0 V
C
5.5 V
0.8 V
"
Q2
"
5
5.5 V
2.0 V
C
5.5 V
-1 mA
"
"
"
"
Q1
"
"
"
6
5.5 V
0.8 V
C
5.5 V
-1 mA
"
"
Q1
"
7
"
-1 mA
5.5 V
C
2.0 V
5.5 V
"
"
"
Q2
"
"
"
8
"
-1 mA
5.5 V
C
0.8 V
5.5 V
"
Q2
"
0.5
3007
9
2.0 V
5.5 V
C
0.8 V
20 mA
"
"
VOL
Q1
"
10
0.8 V
5.5 V
C
2.0 V
20 mA
"
"
Q1
"
"
"
"
"
11
"
20 mA
0.8 V
C
5.5 V
2.0 V
"
Q2
"
12
"
20 mA
2.0 V
C
5.5 V
0.8 V
"
Q2
"
"
"
13
5.5 V
2.0 V
C
5.5 V
20 mA
"
"
"
"
Q1
"
14
5.5 V
0.8 V
C
5.5 V
20 mA
"
"
Q1
"
"
"
"
"
15
"
20 mA
5.5 V
C
2.0 V
5.5 V
"
Q2
"
16
"
20 mA
5.5 V
C
0.8 V
5.5 V
"
Q2
"
"
17
-18 mA
"
"
CLR 1
-1.2
"
VIC
18
-18 mA
"
"
D1
"
"
19
-18 mA
"
"
CLK 1
"
"
20
-18 mA
"
"
PRE 1
"
"
21
"
-18 mA
"
PRE 2
"
"
22
"
-18 mA
"
CLK 2
"
"
23
"
-18 mA
"
D2
"
"
24
"
-18 mA
"
CLR 2
"
"
3009
25
5.5 V
0.5 V
GND
"
5.5 V
D1
-0.5
-2
mA
IIL1
"
26
"
GND
0.5 V
5.5 V
"
D2
-0.5
-2
"
"
27
0.5 V
5.5 V
GND
"
"
CLR 1
-1.5
-6
"
IIL2
"
28
"
GND
5.5 V
0.5 V
"
CLR 2
-1.5
-6
"
"
29
GND
GND
0.5 V
"
"
PRE 1
-1
-4
"
IIL3
"
30
"
0.5 V
GND
GND
"
PRE 2
-1
-4
"
"
31
5.5 V
GND
0.5 V
GND
"
"
CLK 1
-1
-4
"
IIL4
"
32
"
GND
0.5 V
GND
5.5 V
"
CLK 2
-1
-4
"
See footnotes at end of device type 01.
|