MIL-M-38510/758B
3. REQUIREMENTS
3.1 Qualification. Microcircuits furnished under this specification shall be products that are manufactured by a manufacturer
authorized by the qualifying activity for listing on the applicable qualified manufacturers list before contract award (see 4.3 and
6.4).
3.2 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535 and as specified
herein or as modified in the device manufacturer's Quality Management (QM) plan. The modification in the QM plan shall not
affect the form, fit, or function as described herein.
3.3 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535 and herein.
3.3.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.3.2 Truth tables. The truth tables shall be as specified on figure 2.
3.3.3 Switching waveforms and test circuit. The switching waveforms and test circuit shall be as specified on figure 3.
3.3.4 Schematic circuits. The schematic circuits shall be maintained by the manufacturer and made available to the
qualifying activity or preparing activity upon request.
3.3.5 Case outlines. The case outlines shall be as specified in 1.2.3 herein.
3.4 Lead material and finish. The lead material and finish shall be in accordance with MIL-PRF-38535 (see 6.6).
3.5 Electrical performance characteristics and post irradiation end-point electrical parameter limits. Unless otherwise
specified, the electrical performance characteristics and postirradiation end-point electrical parameter limits are as specified in
table I and apply over the case operating temperature range specified. Test conditions for these specified characteristics and
limits are as specified in table I.
3.6 Electrical test requirements. The electrical test requirements for each device class shall be the subgroups specified in
table II. The electrical tests for each subgroup are described in table I. Radiation hardness assurance level M, D, P, L, and R
(see MIL-PRF-38535) in table I are postirradiation end-point electrical parameters.
3.7 Marking. Marking shall be in accordance with MIL-PRF-38535.
3.7.1 Radiation hardness assurance identifier. The radiation hardness assurance identifier shall be in accordance with
MIL-PRF-38535 and herein (see 3.6).
3.8 Microcircuit group assignment. The devices covered by this specification shall be in microcircuit group number 39 (see
MIL-PRF-38535, appendix A).