| MIL-M-38510/762A
Table II. Burn-in and electrical test requirements.
Class B device
1/
Applicable tests and
Class S device
1/
Line no. MIL-STD-883 test
method
Reference
Table I
Table III delta
Reference
Table I
Table III delta
paragraphs
subgroups 2/
limits 3/
paragraphs
subgroups 2/
limits 3/
Interim electrical
1
parameters
1
1
(method 5004)
Static burn-in I
4.2b
5/
Not required
2
(method 1015)
4.5.2
Required
3
Same as line 1
1
delta
4
Static burn-in II
4.2b
5/
4.2b
4/
(method 1015)
4.5.2
Required
4.5.2
5
Same as line 1
4.2d
1*
delta
4.2d
1*
delta
6
Dynamic burn-in
4.2b
5/
Not required
(method 1015)
4.5.2
Required
7
Same as line 1
4.2d
1
delta
Final electrical
8
parameters
1*, 2, 7, 9
1*, 2, 7, 9
(method 5004)
4/
Group A test
9
requirements
4.4.1
1, 2, 3, 4, 7, 8,
4.4.1
1, 2, 3, 4, 7, 8,
(method 5005)
9, 10, 11
9, 10, 11
Group B end-point
10
electrical parameters
4.4.2
1, 2, 3, 7, 8, 9,
delta
(method 5005)
10, 11
Group C end-point
11
electrical parameters
4.4.3
1,2
delta
(method 5005)
Group D end-point
12
electrical parameters
4.4.4
1, 2, 3
4.4.4
1, 2
(method 5005)
Group E end-point
13
electrical parameters
4.4.5
1, 7, 9
4.4.5
1, 7, 9
(method 5005)
See footnotes at end of table.