MIL-M-38510/79D
TABLE I. Electrical performance characteristics - Continued.
Conditions
Limits
Device
Units
Test
Symbol
-55C TC +125C
Min
Max
type
Unless otherwise specified
VCC = 5.0 V
05
2.0
22.0
ns
From strobe to W
tLZ2
CL = 50 pF
From select to Y
06
2.0
22.0
ns
tPLH1
RL = 280
07
18.5
From select to Y
06
2.0
22.0
ns
tPHL1
07
18.5
From data to Y
06
2.0
12.0
ns
tPLH2
07
10.0
From data to Y
06
2.0
11.0
ns
tPHL2
07
10.0
From output control to Y
05, 06
2.0
28.0
ns
tZH
07
28.0
08
30.0
From output control to Y
05, 06
2.0
30.0
ns
tZL
07
30.0
08
31.0
From output control to Y
05, 06
2.0
24.0
ns
tHZ
07
24.0
08
18.0
From output control to Y
05, 06
2.0
22.0
ns
tLZ
07
22.0
08
20.0
1/ Not more than one output should be shorted at one time.