| TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated may be H > 2.0 V, or L < 0.8 V, or open)
Cases
Test limits
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
E,F
MIL-
Measured
Unit
Subgroup
Symbol STD-883 X, 2 5/
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Min
Max
terminal
method
Test no.
D3
D2
D1
D0
Y
W
ST
GND
C
B
A
D7
D6
D5
D4
VCC
9
3003
107
IN
OUT
GND
GND
GND
GND
GND
5.0 V
Y
2.0
14.0
ns
tPHL6
Fig. 4
108
IN
"
"
"
"
GND
2.7 V
"
"
"
"
"
TC = +25C
"
109
IN
"
"
"
"
2.7 V
GND
"
"
"
"
"
"
110
IN
"
"
"
"
2.7 V
"
"
"
"
"
2.7 V
"
111
"
"
"
2.7 V
GND
GND
IN
"
"
"
"
"
"
112
"
"
"
"
GND
2.7 V
IN
"
"
"
"
"
"
113
"
"
"
"
2.7 V
GND
IN
"
"
"
"
"
"
114
"
"
"
"
2.7 V
2.7 V
IN
"
"
"
"
"
"
115
IN
"
"
"
GND
GND
GND
"
"
"
"
"
tPLH6
"
116
IN
"
"
"
"
GND
2.7 V
"
"
"
"
"
"
117
IN
"
"
"
"
2.7 V
GND
"
"
"
"
"
"
118
IN
"
"
"
"
2.7 V
"
"
"
"
"
2.7 V
"
119
"
"
"
2.7 V
GND
GND
IN
"
"
"
"
"
"
120
"
"
"
"
GND
2.7 V
IN
"
"
"
"
"
"
121
"
"
"
"
2.7 V
GND
IN
"
"
"
"
"
"
122
"
"
"
"
2.7 V
2.7 V
IN
"
"
"
"
"
10
"
123
2.7 V
GND
OUT
"
"
GND
GND
IN
"
W
"
20
"
tPHL1
"
124
2.7 V
"
"
"
"
GND
IN
GND
"
"
"
"
"
TC = +125C
"
125
"
"
"
"
IN
GND
GND
2.7 V
"
"
"
"
"
"
126
2.7 V
"
"
"
"
GND
GND
IN
"
"
"
22
"
tPLH1
"
127
2.7 V
"
"
"
"
GND
IN
GND
"
"
"
"
"
"
128
"
"
"
"
IN
GND
GND
2.7 V
"
"
"
"
"
"
129
2.7 V
"
OUT
"
"
GND
GND
IN
"
Y
"
26
"
tPHL2
"
130
2.7 V
"
"
"
"
GND
IN
GND
"
"
"
"
"
"
131
"
"
"
"
IN
GND
GND
2.7 V
"
"
"
"
"
"
132
2.7 V
"
"
"
"
GND
GND
IN
"
"
"
"
"
tPLH2
"
133
2.7 V
"
"
"
"
GND
IN
GND
"
"
"
"
"
"
134
"
"
"
"
IN
GND
GND
2.7 V
"
"
"
"
"
"
135
2.7 V
OUT
IN
"
GND
"
"
"
W
"
18
"
tPHL3
"
136
"
OUT
"
"
"
"
"
"
W
"
19.5
"
tPLH3
"
137
"
OUT
"
"
"
"
"
"
Y
"
26
"
tPHL4
"
138
"
OUT
"
"
"
"
"
"
Y
"
24
"
tPLH4
See footnotes at end of device type 02
|