| TABLE III. Group A inspection for device type 02 Continued.
Terminal conditions (pins not designated may be H > 2.0 V, or L < 0.8 V, or open)
Cases
Test limits
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MIL-
E,F
Measured
STD-883 X, 2 5/
Unit
Subgroup
Symbol
2
3
4
5
7
8
9
10
12
13
14
15
17
18
19
20
Min
Max
terminal
method
Test no.
1G
B
1C3
1C2
1C1
1C0
1Y
GND
2Y
2C0
2C1
2C2
2C3
A
2G
VCC
10
3003
95
GND
GND
IN
OUT
GND
GND
5.0 V
1Y
2.0
14.5
ns
tPHL1
Fig. 5
96
"
GND
IN
"
"
2.7 V
"
"
"
"
"
TC = +125C
"
97
"
2.7 V
IN
"
"
GND
"
"
"
"
"
"
98
"
2.7 V
IN
"
"
2.7 V
"
"
"
"
"
"
99
GND
"
OUT
GND
GND
"
2Y
"
"
"
IN
"
100
GND
"
"
IN
2.7 V
"
"
"
"
"
"
"
101
2.7 V
"
"
IN
GND
"
"
"
"
"
"
"
102
2.7 V
"
"
IN
2.7 V
"
"
"
"
"
"
"
103
GND
GND
IN
OUT
"
GND
"
1Y
"
14.5
"
tPLH1
"
104
"
GND
IN
"
"
2.7 V
"
"
"
"
"
"
105
"
2.7 V
IN
"
"
GND
"
"
"
"
"
"
106
"
2.7 V
IN
"
"
2.7 V
"
"
"
"
"
"
107
GND
"
OUT
GND
GND
"
2Y
"
"
"
IN
"
108
GND
"
"
IN
2.7 V
"
"
"
"
"
"
"
109
2.7 V
"
"
IN
GND
"
"
"
"
"
"
"
110
2.7 V
"
"
IN
2.7 V
"
"
"
"
"
"
"
111
GND
GND
GND
2.7 V
OUT
"
IN
"
1Y
"
26
"
tPHL2
"
112
GND
IN
GND
2.7 V
OUT
"
GND
"
1Y
"
"
"
"
113
GND
"
OUT
2.7 V
GND
IN
GND
"
"
"
"
2Y
"
114
IN
"
OUT
2.7 V
GND
GND
GND
"
2Y
"
"
"
"
115
GND
GND
GND
2.7 V
OUT
"
IN
"
1Y
"
26
"
tPLH2
"
116
GND
IN
GND
2.7 V
OUT
"
GND
"
1Y
"
"
"
"
117
GND
"
OUT
2.7 V
GND
IN
GND
"
"
"
"
2Y
"
118
IN
"
OUT
2.7 V
GND
GND
GND
"
2Y
"
"
"
"
119
IN
GND
2.7 V
OUT
"
"
IN
"
1Y
"
21
"
tPHL3
"
120
"
"
OUT
2.7 V
"
"
2Y
"
21
"
"
121
IN
"
2.7 V
OUT
"
"
IN
"
1Y
"
22
"
tPLH3
"
122
"
"
OUT
2.7 V
"
"
2Y
"
22
"
11
Same tests, terminal conditions, and limits as for subgroup 10 except TC = -55C.
1/
For circuit B, IOS(max) = -110 mA
2/ Only a summary of attributes is required.
3/ A = 2.4 V; B = 0.4 V.
4/ H > 1.5 V; L < 1.5 V.
5/ Case 2 pins not designated are NC.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |