Click here to make tpub.com your Home Page

Page Title: Table 3. Group A inspection for device type 01-cont.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
TABLE III. Group A inspection for device type 01 Continued.
Terminal conditions (pins not designated may be high 2.0 V, low 0.8 V, or open)
Subgroup
Symbol
MIL-STD-
Cases
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Measured
Limits
Unit
883
A,B,C,D
terminal
method
Cases
2
3
NC
6
8
9
10
12
13
14
NC
18
19
20
X and 2
Test no.
1A
1B
NC
1C
1D
1Y
GND
2Y
2A
2B
NC
2C
2D
VCC
Min
Max
1
IIL
3009
45
0.5 V
5.5 V
5.5 V
5.5 V
GND
5.5 V
5.5 V
5.5 V
5.5 V
5.5 V
1A
-2
-4
mA
TC=+25C
46
5.5 V
0.5 V
"
"
"
"
"
"
"
"
1B
"
"
"
47
"
5.5 V
0.5 V
"
"
"
"
"
"
"
1C
"
"
"
48
"
"
5.5 V
0.5 V
"
"
"
"
"
"
1D
"
"
"
49
"
"
"
5.5 V
"
0.5 V
"
"
"
"
2A
"
"
"
50
"
"
"
"
"
5.5 V
0.5 V
"
"
"
2B
"
"
"
51
"
"
"
"
"
"
5.5 V
0.5 V
"
"
2C
"
"
"
52
"
"
"
"
"
"
"
5.5 V
0.5 V
"
2D
"
"
"
ICCL
3005
53
"
"
"
"
"
"
"
5.5 V
5.5 V
"
VCC
44
"
ICCH
3005
54
GND
GND
GND
GND
"
GND
GND
GND
GND
"
VCC
18
"
A
ICEX
55
GND
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
5.5 V
5.5 V
5.5 V
"
1Y
250
ICEX
56
5.5 V
5.5 V
5.5 V
5.5 V
"
5.5 V
GND
5.5 V
5.5 V
5.5 V
"
2Y
250
A
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125C and VIC tests are omitted. 1/ 2/
2
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55C and VIC tests are omitted. 2/
3
9
tPHL
3003
57
IN
2.7 V
2.7 V
2.7V
OUT
GND
5.0 V
1A to 1Y
2
10.0
ns
TC=+25C
Fig. 3
58
"
OUT
IN
2.7 V
2.7 V
2.7 V
"
2A to 2Y
"
"
"
tPLH
3003
59
IN
2.7 V
2.7 V
2.7V
OUT
"
"
1A to 1Y
"
"
"
Fig. 3
60
"
OUT
IN
2.7 V
2.7 V
2.7 V
"
2A to 2Y
"
"
"
10
tPHL
3003
61
IN
2.7 V
2.7 V
2.7V
OUT
"
"
1A to 1Y
"
10.0
"
TC=+125C
Fig. 3
62
"
OUT
IN
2.7 V
2.7 V
2.7 V
"
2A to 2Y
"
"
"
tPLH
3003
63
IN
2.7 V
2.7 V
2.7V
OUT
"
"
1A to 1Y
"
"
"
Fig. 3
64
"
OUT
IN
2.7 V
2.7 V
2.7 V
"
2A to 2Y
"
"
"
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55C.
11
1/ For tests 3 through 10, VIL = 0.7 V.
For tests 1 and 2, VOL (max) = 0.45 V.
2/ For tests 11 through 18, IOH = -30 mA.

Privacy Statement - Press Release - Copyright Information. - Contact Us