| TABLE III. Group A inspection for device type 01.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
MIL-
Meas.
Case A,B,C,D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Subgroup
Symbol
STD-883
terminal
Min
Max
Unit
Test No.
SI
A
B
C
D
MC
GND
CLK2
CLK1
QD
QC
QB
QA
VCC
method
2.4
V
1
3006
1
2.0 V
2.0 V
GND
A 1/
-.8 mA
4.5 V
VOH
QA
"
"
2
2.0 V
"
"
"
-.8 mA
"
"
"
TC = 25C
QB
"
"
"
"
"
3
2.0 V
"
"
"
-.8 mA
"
QC
"
"
"
"
"
4
2.0 V
"
"
"
-.8 mA
"
QD
3007
5
0.8 V
"
"
"
16 mA
"
0.4
"
"
QA
VOL
"
"
"
"
"
6
0.8 V
"
"
"
16 mA
"
QB
"
"
"
"
"
7
0.8 V
"
"
"
16 mA
"
QC
"
"
'`
"
"
8
0.8 V
"
"
"
16 mA
"
QD
"
9
-12 mA
"
"
SI
-1.5
"
VIC
"
"
10
-12 mA
"
"
A
"
"
"
"
11
-12 mA
"
"
B
"
"
"
"
12
-12 mA
"
"
C
"
"
"
"
13
-12 mA
"
"
D
"
"
"
"
14
-12 mA
"
"
MC
"
"
"
"
15
"
-12 mA
"
CLK2
"
"
"
"
"
16
"
-12 mA
"
CLK1
"
3009
17
0.4 V
GND
"
5.5 V
SI
2/
"
IIL1
"
"
"
18
0.4 V
4.5 V
"
"
A
"
"
"
"
19
0.4 V
"
"
"
B
"
"
"
"
20
0.4 V
"
"
"
C
"
"
"
"
21
0.4 V
"
"
"
D
"
"
"
"
22
"
"
0.4 V
"
CLK2
"
"
"
"
23
GND
"
0.4 V
"
CLK1
"
"
"
24
0.4 V
"
4.5 V
"
MC
3/
IIL2
A
3010
25
2.4 V
4.5 V
"
"
SI
40
"
IIH1
"
"
"
26
2.4 V
GND
"
"
A
"
"
"
"
"
27
2.4 V
"
"
"
B
"
"
"
"
"
28
2.4 V
"
"
"
C
"
"
"
"
"
29
2.4 V
"
"
"
D
"
"
"
"
"
30
"
"
2.4 V
"
CLK2
"
"
"
"
"
31
4.5 V
"
2.4 V
"
CLK1
"
"
3010
32
5.5 V
4.5 V
"
"
SI
100
"
"
IIH2
"
"
"
33
5.5 V
GND
"
"
A
"
"
"
"
"
34
5.5 V
"
"
"
B
"
"
"
"
"
35
5.5 V
"
"
"
C
"
"
"
"
"
36
5.5 V
"
"
"
D
"
"
"
"
"
37
"
"
5.5 V
"
CLK2
"
"
"
"
"
38
4.5 V
"
5.5 V
"
CLK1
"
"
See footnotes at end of device type 01.
|