| TABLE III. Group A inspection for device type 06 - Continued.
Terminal conditions (pins not designated may be H > 2.0 V or L < 0.8 V or open).
MIL-
Cases E, F
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Test limits
Subgroup
Symbol
STD-883
Meas.
terminal
Min
Max
Unit
method
Test No.
CLR
J
A
B
C
D
GND
SL
CLK
K
QD
QC
QB
QA
VCC
QD
7
Truth
3014
85
A
B
B
B
A
B
A
GND
B
B
H
L
H
L
H
5.0 V
table
"
86
"
"
"
B
"
B
"
"
"
A
L
H
L
H
L
"
TC = 25C
3/ 6/
test
"
87
"
"
"
A
"
A
"
"
"
A
"
"
L
"
L
"
"
5/
"
88
"
"
"
"
"
"
"
"
"
B
"
"
L
"
L
"
"
"
"
89
"
"
"
"
"
"
"
"
"
A
"
"
H
"
H
"
4/
"
"
"
90
B
"
"
"
"
"
"
"
"
B
H
L
L
L
L
"
"
"
"
91
B
"
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
"
"
92
B
A
A
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
93
A
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
94
B
"
"
"
"
"
"
"
A
"
"
"
"
"
"
"
"
"
"
95
A
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
96
A
"
"
B
B
B
B
"
"
B
"
"
"
"
"
"
"
"
"
97
A
"
"
B
B
B
B
"
"
A
"
"
"
"
H
"
8
Repeat subgroup 7 at except TC = 125C and TC = -55C.
9
(Fig 9)
98
B
5.0 V
GND
GND
5.0 V
IN
OUT
5.0 V
15
MHz
fMAX
QA
3003
99
IN
5.0 V
5.0 V
5.0 V
5.0 V
GND
GND
"
OUT
"
7
30
ns
TC = 25C
tPHL1
CLR to QA
"
"
(Fig 9)
100
"
"
"
"
"
"
"
"
OUT
"
"
"
"
CLR to QB
"
"
"
101
"
"
"
"
"
"
"
"
OUT
"
"
"
"
CLR to QC
"
"
"
102
"
"
"
"
"
"
"
"
OUT
"
"
"
"
CLR to QD
"
103
B
IN
"
IN
"
OUT
"
"
"
24
"
CLK to QA
tPHL2
"
"
"
104
"
IN
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
105
"
IN
"
"
"
OUT
"
"
"
"
CLK to QC
"
"
"
106
"
IN
"
"
"
OUT
"
"
"
"
CLK to QD
"
107
"
IN
"
"
"
OUT
"
"
"
29
"
CLK to QA
tPHL2
"
"
"
108
"
IN
"
"
"
OUT
"
"
"
"
CLK to QB
"
"
"
109
"
IN
"
"
"
OUT
"
"
"
"
CLK to QC
"
"
"
110
"
IN
"
"
"
OUT
"
"
"
"
CLK to QD
See footnotes at end of device type 06.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |