| ![]() MIL-M-45405C(AR)
4.4
Ouality Conformance Inspection.
Inspection lot formation.
Inspection lots shall comply
4.4.1
with the lot formation provisions of MIL-A-48078,
In addition, each
Inspection lot shall contain:
a. Metal parts assemblies of one lot interfix number from
one manufacturer.
b.
Boosters of one lot interfix number from one
manufacturer.
c.
Primers of one lot interfix number from one
(See 4.4.5)
manufacturer.
HBX-6 (H-6) of one lot interfix number from one
d.
manufacturer.
Black powder of one lot interfix number from one
e.
manufacturer.
REX of one lot interfix number from one manufacturer.
f.
Lead azide of one lot interfix number from one
g.
manufacturer.
h.
Delay composition of one lot interfix number from one
manufacturer.
4.4.2
Examination.
See MIL-A-48078.
Sampling plans . Unless otherwise specified in the
a.
Classification of Defects and Test Tables, sampling plans and
procedures for major and minor defects shall be in accordance with
MIL-STD-105, Inspection Level II.