| MIL-M-45986(WC)
TABLE I
FUNCTION FIRING 1/
1/ All charges shall be conditioned and fired at 135 F to 145 F.
2/ Any standard projectile loaded to 103 1 pounds.
3.3.3 Friction. Friction oof the recoil rod, when assembled in the
recoil cylinder and the floating piston assembly, shall be within the
limits specified in Table 11 after assembly, and Table III after function
TABLE II
(After Assembly)
FRICTION IN POUNDS PER SQUARE INCH(PSI)
HYDRAULIC PRESSURE
Max. Limits
Part Name
35 PSI
REPLENISHER, PISTON D12007613
15o PSI
ROD, RECOIL F12007661
60 PSI
RECUPERATOR, FLOATING PISTON ASSY.
7
|