| MIL-M-50383A(MU)
F5549108
Telescope, Collimating
F6523553
F i x t u r e , Elevation & Cross Level Testing
A8658940
I n s p e c t i o n Aid
F10553898
I n s p e c t i o n Aid
F10555619
T e s t Fixture
PACKAGING DATA SHEET
10553215
Packaging of Mount, Telescope: M134A1
( C o p i e s of specifications, s t a n d a r d s , drawings and packaging data sheets
r e q u i r e d by suppliers in connection with specific procurement functions
s h o u l d be obtained from the procuring activity or as directed by the
contracting officer.)
3.
REQUIREMENTS
3 . 1 Regulations pertaining to radioactive devices. - Marking,
i d e n t i f i c a t i o n , handling, and shipping of radioactive devices shall be
in accordance with MIL-STD-1458.
3 . 2 F a b r i c a t i o n . - The mount shall be manufactured in accordance
with Drawing F10553215.
3.3 General specification. -
T h e following requirements of
MIL-F-13926 shall be met:
a . Order of precedence
b . D i m e n s i o n s and tolerances
c . I n o r g a n i c protective surface finishes
d . P a r t identification and marking
e . Workmanship
3.4 Environmental.
Storage t emperatures. - The mount shall show no evidence of
3.4.1
p h y s i c a l failure due to being thermally stabilized at -80 and +160
F a h r e n h e i t (F).
Operating temperatures. - T h e mount shall meet the applicable
3.4.2
r e q u i r e m e n t s of 3.5.11 while thermally stabilized at -40 and +150F.
3 . 4 . 3 V i b r a t i o n . - T h e mount shall be
vibrated in
a vertical plane
a t a constant frequency of thirty cycles per
second with
an amplitude
o f 1/16 inch (1/8 inch total excursion) for
a period of
five minutes
p l u s or minus fifteen seconds. S u b s e q u e n t
to vibration
there shall
b e no evidence of physical failure.
3.5
Performance.
2
|