| MIL-M-50512 (MU)
4.2.2 Examination.-The examinations listed in the follow-
ing subparagraphs shall be performed on inspection lots (see 4.2.1)
of the components or assemblies designated in the applicable
paragraph headings. Inspection for critical defects (and major
defects, when so specified) shall be 100 percent. Sampling plans
for major and minor defects shall be in accordance with MIL-
STD-105 except that continuous sampling plans in accordance with
MIL-STD-1235 may be used if approved by the Government. Instead
of applying the AQL's designated herein to the groups of major
and minor defects listed, the contractor may elect to apply
AQL's to individual defects using an AQL of 0.40 percent for
each major defect and an AQL of 0.65 percent for each minor defect.
When this method is elected, it shall be applied to all of the
major and minor defects listed in the applicable subparagraphs
of this section, except where 100 percent inspection Is specified,
and be documented as part of the contractor's inspection system.
4.2.2.1 Mine, APERS, Practice, M68 (see dwg. 9251503).
4.2.2.2
Carton, prior to sealing (see dwg. 8800901).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |