| M1L-M-53008(ME)
3.
REQUIREMENTS
3.1 Description. Requirements for the mounting kit shall be in accordance
with TA13222E0026 and as specified herein.
3.2 Drawings. The drawings forming a part of this specification are end
product drawings. No deviations from the prescribed dimensions or tolerances are
permissible without prior approval of the contracting officer. Where tolerances
could cumulatively result in incorrect fits, the contractor shall provide
tolerances within those prescribed on the drawings to insure correct fit,
assembly, and operation of the kit. Any data (e.g., shop drawings, layouts, flow
sheets, processing procedures, etc.) prepared by the contractor or obtained from
a vendor to support fabrication and manufacture of the production item shall be
made available, upon request, for inspection by the contracting officer or his
designated representative.
3.3 First article (first produced kit). The contractor shall furnish one or
more kits as specified (see 6.2), for examination within the time-frame specified
(see 6.2), to prove that his production methods will produce kits that comply
with the requirements of this specification. Examination shall be specified
in Section 4 and shall be subject to surveillance and approval by the Government
(see 6.3).
3.4 Materials. Materials shall be as specified on the applicable drawings.
Materials not specified shall be selected by the contractor and shall be subject
to all provisions of this specification (see 6.4).
3.5 Safety. Nonfunctional sharp edges, projecting points, and excessive
length of fastening devices shall be avoided.
All parts having the same part number shall be
3.6 Interchangeability.
functionally and dimensionally interchangeable. Interchangeable parts are
defined as two or more like parts possessing such functional and physical
characteristics as to be equivalent in performance and durability and capable of
being exchanged one for the other without alteration of the parts themselves, or
of adjoining parts, and without selection for fit or performance.
3.7 Treatment and Painting.
3.7.1 External. The portions of the kit, externally located on the tank,
normally painted shall be cleaned, treated, and painted in accordance with
MIL-T-704, Type A color forest green.
3.7.2 Internal. The portions of the kit, internally located on the tank,
normally painted shall be cleaned, treated, and painted in accordance with
MIL-T-704, Type A, color white enamel.
3.7.3 Dissimilar Metals. Nonpermissible galvanic couples (dissimilar metals),
as defined in MIL-T-704, shall be insulated as specified.
3
|