| MIL-M-53077(ME)
4.4.2 Examination. Samples selected in accordance with 4.4.2 shall be examined in
accordance with 4.5.1 and tested in accordance with 4.5.2.1. Acceptable quality level (AOL)
shall be 1.0 percent defective for major defects and 2.5 percent for minor defects.
4.5 Inspection schedule.
4.5.1 Examination. Units for examination shall be examined in accordance with table I,
examination schedule.
4.5.1.1 Examination conditions. Unless otherwise specified, conformance examination shall be
performed by the contractor at the contractor's location, and witnessed by the Government.
4.5.1.2 Examination procedures (first article). One or more first article kits, selected at
random, shall be examined for conformance to dimensions specified on the drawings.
TABLE I. Examination schedule.
First
Quality
Requirement
Article
Conformance
Characteristics
Paragraph
MAJOR
X
X
101.
Dimensions not as specified.
3.2
X
X
102.
Parts and components not as specified.
3.2
X
X
103.
Material not as specified.
3.4
X
X
104.
Materials are not resistant to corrosion or
3.4.1
deterioration for the applicable storage and
operating environment.
X
X
105. Dissimilar metals as defined in
3.4.1.1
MIL-STD-889 are not effectively insulated
from each other.
X
X
106. Contractor does not have documentation
3.4.1.2
available for identification of materials,
material finishes, or treatments.
10
|