| MIL-M-63321A(AR)
FIGURE 12. Static discharge test circuit.
a.. Measure input current, high level
and low level
25C 5C at one input terminal of device under test (DUT).
at 25C 5C. The test
Also measure quiescent device current
limit for a single terminal measurement of
and
and
shall
be increased a maximum of 10% of their value specified in the electrical
characteristic Table II.
b. Apply the static discharge
to the DUT in each of the
following modes by charging C1 to
with S1 in position 1 and then
switching to position 2.
c. Within 24 hours repeat the
and
measurements
on the same terminals as performed above. If the DUT exhibits leakage
currents in excess of the specified test limit (see a) at this time, it is
defective. (Destructive test).
|