| MIL-M-63457A(AR)
4.4 Quality conformance inspection
4.4.1 Inspection lot formation. Inspection lots shall comply
with the lot formation provisions of MIL-A-48078. In addition,
inspection lots of mines shall contain:
a. S&A Assemblies (Dwg. 9328692) of one lot interfix from
one manufacturer.
b. Electronics-MCD Assemblies (Dwg. 9330379) of one lot
interfix number from one manufacturer .
c. Main Charge (Dwg. 9278018) of one explosive lot interfix
number from one manufacturer .
d. Booster (Dwg. 9277827) of one explosive lot interfix
number from one manufacture .
e. Propellant Cup Assemblies (Dwg. 9292175) of one lot
interfix from one manufacturer.
f. M-S plates of one lot interfix number from one
manufacturer.
Maximum lot size shall be no more than one (1) month production
(30 calendar day period).
(See MIL-A-48078) and 4.4.2.1 thru
4.4.2 Examination.
4.4.2.9. Unless otherwise specified in the Classification of
Defects and Tests tables, sampling plans and procedures for major
and minor defects shalll be in accordance with MIL-STD-105.
|